It is reported in the literature article titled ¿prophylactic clip closure for mucosal defects is associated with reduced adverse events after colorectal endoscopic submucosal dissection: a propensity-score matching analysis¿ patients experienced perforation and/or bleeding events during or after procedures using olympus devices.Case with patient identifier (b)(6) reports kd-655q, case with patient identifier (b)(6) reports hx-610-090l, case with patient identifier (b)(6) reports hx-202ur, case with patient identifier (b)(6) reports pcf-h290z1, case with patient identifier (b)(6) reports pcf-q260ai.Study background and aim it is unclear whether prophylactic endoscopic closure after colorectal endoscopic submucosal dissection (esd) reduces the risk of postoperative adverse events due to variability in lesion characteristics.Therefore, we conducted a retrospective study using propensity score matching to evaluate the efficacy of prophylactic clip closure in preventing postoperative adverse events after colorectal esd methods: this single-center retrospective cohort study included 219 colorectal neoplasms which were removed by esd.The patients were allocated into the closure and non-closure groups, which were compared before and after propensity-score matching.Post-esd adverse events including major and minor bleeding and delayed perforation were compared between the two groups.Results: in this present study, 97 and 122 lesions were allocated to the closure and non-closure groups, respectively, and propensity score matching created 61 matched pairs.The rate of adverse events was significantly lower in the closure group than in the non-closure group (8% vs.28%, p=0.008).Delayed perforation occurred in two patients in the non-closure group, whereas no patient in the closure group developed delayed perforation.In contrast, there were no significant differences in other postoperative events including the rate of abdominal pain; fever, white blood cell count, and c-reactive protein; and appetite loss between the two groups.Conclusions: propensity score matching analysis demonstrated that prophylactic closure was associated with a significantly reduced rate of adverse events after colorectal esd.When technically feasible, mucosal defect closure after colorectal esd may result in a favorable postoperative course.The total number of adverse events after colorectal esd, including delayed perforation and post-esd bleeding, was significantly higher in the non-closure group than in the closure group (28% vs.6%, p < 0.001).Similarly, the proportion of patients with fever was significantly higher in the non-closure group than in the closure group (12% vs.2%, p=0.019).However, there were no significant differences in the proportion of patients with abdominal pain, wbc count, c-reactive protein levels, and appetite loss between the two groups.There is no report of any olympus device malfunction reported in any procedure described in this literature.
|