Model Number G2200
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Pressure Problem (3012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/18/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a water vapor therapy, the generator displayed error code 465 (water pressure self test error).The staff was unable to clear the error; therefore, the procedure was not completed.There were no patient complications.This event is being reported for aborted/cancelled procedure with a patient under anesthesia.
 
Additional Manufacturer Narrative
Upon receipt of this generator at our quality assurance laboratory, this device was thoroughly analyzed.Analysis of the device was unable to replicate the fault 465 (water pressure self-test error) code.No error codes appeared during functional testing.The generator passed the post (power on self-test).The syringe and delivery device were connected with no issues.The generator primed and flushed as per specifications.The generator received all required updates.The generator was received with minor plastic enclosure damage.Most likely due to normal usage wear.Those parts were replaced.The rest of the generator was in overall good physical condition.Based on the issue that there were no errors, an evaluation conclusion code of no problem detected was assigned to this investigation.
 
Event or Problem Description
It was reported that during a water vapor therapy, the generator displayed error code 465 (water pressure self test error).The staff was unable to clear the error; therefore, the procedure was not completed.There were no patient complications.This event is being reported for aborted/cancelled procedure with a patient under anesthesia.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REZUM
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
alyson harris
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key14626305
Report Number2124215-2022-20050
Device Sequence Number5013766
Product Code GEI
UDI-Device Identifier08714729986843
UDI-Public08714729986843
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K180237
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/16/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberG2200
Device Catalogue NumberG2200
Device Lot Number0000003112
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/01/2022
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/18/2022
Supplement Date Received by Manufacturer08/30/2022
Initial Report FDA Received Date06/07/2022
Supplement Report FDA Received Date09/16/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/13/2016
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-