MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH SCORPIO NRG CR FEMORAL COMPONENT RIGHT #5; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH SCORPIO NRG CR FEMORAL COMPONENT RIGHT #5; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL Back to Search Results
Model Number 80-4405R
Device Problems Unstable (1667); Osseointegration Problem (3003); Migration (4003)
Patient Problems Arthritis (1723); Insufficient Information (4580)
Event Date 05/12/2022
Event Type  Injury  
Manufacturer Narrative
Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.
 
Event Description
Aseptic mobilization of the prosthesis.Reason the device was used: right knee osteoarthritis.Total right knee replacement.Year of implant: 2017.
 
Manufacturer Narrative
An event regarding instability and loosening involving a scorpio femoral component was reported.Instability was confirmed via review of the provided medical records by a clinical consultant.Loosening was not confirmed.Method & results: -product evaluation and results: the reported device was not returned however photographs were provided for review.Visual inspection of the provided photographs of the device indicated that the device has cement adhered to the bone-interfacing side of the device.There is nothing remarkable to note.-clinician review: a review of the provided medical information by a clinical consultant indicated: "this patient underwent a cemented scorpio total knee arthroplasty in 2017.According to the summary the implant was removed on (b)(6), 2022 for "aseptic loosening of the prosthesis." i cannot confirm that revision occurred since i have no supporting evidence to document this such as office notes, an operation note or post revision x-rays.I also cannot confirm that aseptic loosening of the prosthesis occurred.The x-rays provided, in my opinion show that the patient has gross instability of the implant.I see no evidence of loosening of either the femoral or tibial component but, granted, only two x-rays are provided.The causes of late instability of a cemented total knee arthroplasty are multifactorial including surgical technique, patient factors including bmi and activity level.It would be unusual to implicate implant factors as a cause of instability." -product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that the patient was revised due to aseptic loosening.The reported device was not returned however photographs were provided for review.Visual inspection of the provided photographs of the device indicated that the device has cement adhered to the bone-interfacing side of the device.There is nothing remarkable to note.A review of the provided medical information by a clinical consultant indicated: "this patient underwent a cemented scorpio total knee arthroplasty in 2017.According to the summary the implant was removed on (b)(6), 2022 for "aseptic loosening of the prosthesis." i cannot confirm that revision occurred since i have no supporting evidence to document this such as office notes, an operation note or post revision x-rays.I also cannot confirm that aseptic loosening of the prosthesis occurred.The x-rays provided, in my opinion show that the patient has gross instability of the implant.I see no evidence of loosening of either the femoral or tibial component but, granted, only two x-rays are provided.The causes of late instability of a cemented total knee arthroplasty are multifactorial including surgical technique, patient factors including bmi and activity level.It would be unusual to implicate implant factors as a cause of instability." no further investigation for this event is possible at this time.If devices and/or additional information become available to indicate further evaluation is warranted, this record will be reopened.
 
Event Description
Aseptic loosening of the prosthesis.Reason the device was used: right knee osteoarthritis.Total right knee replacement.Year of implant: 2017.Update per med review: "there is rather profound anterior subluxation of the tibia on femur indicating gross instability.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SCORPIO NRG CR FEMORAL COMPONENT RIGHT #5
Type of Device
PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
joann ripoli
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key14634103
MDR Text Key293569961
Report Number0002249697-2022-00810
Device Sequence Number1
Product Code JWH
UDI-Device Identifier07613327030303
UDI-Public07613327030303
Combination Product (y/n)N
Reporter Country CodeIT
PMA/PMN Number
K042343
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Health Professional
Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date 10/21/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/08/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date04/30/2021
Device Model Number80-4405R
Device Catalogue Number80-4405R
Device Lot NumberDY2A72
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received09/30/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/05/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention; Hospitalization;
-
-