Model Number 370-1580-01
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/25/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The sample is indicated as available for return.As of the date of this report, the sample has not been returned.A follow-up report will be provided once the device has been received and reviewed.
 
Event or Problem Description
The tissue could not be taken out; this incident was used with a coaxial guide needle.The gun was not tested before use.When the instrument was taken out, it was rotated 360 degrees.The range of use was 23mm.The empty gun occurred at the first needle.
 
Additional Manufacturer Narrative
A review of the dhrs of the top level and sublots as well as the inspection records was conducted, and no deviations or non-conformances were found relating to this issue.One opened sample was returned from the customer for review.A visual inspection was performed on the returned product and it was found that the pincer was flattened, inhibiting it from properly obtaining a sample.There are stringent computer/photographic inspections that ensure the pincer is not deformed during the manufacturing process and has the proper radius.When the device is cocked, the pincer comes out of its window and becomes exposed to the tissues and structures present during the operation.Without the use of a proper sized coaxial needle, such as the inner diameter being too small, the pincer can be pushed flat.It is also possible that the needle set was inserted into tissue that was too hard for the sensitive pincer, pushing it flat.Since the most likely cause for the damaged needles is related to an event within the user's environment and not a manufacturing issue, no corrective action can be implemented at this time.
 
Event or Problem Description
The tissue could not be taken out; this incident was used with a coaxial guide needle.The gun was not tested before use.When the instrument was taken out, it was rotated 360 degrees.The range of use was 23mm.The empty gun occurred at the first needle.
 
Event or Problem Description
The tissue could not be taken out; this incident was used with a coaxial guide needle.The gun was not tested before use.When the instrument was taken out, it was rotated 360 degrees.The range of use was 23mm.The empty gun occurred at the first needle.
 
Additional Manufacturer Narrative
The sample is indicated as returned.As of the date of this report, the sample has not been evaluated.A follow-up report will be provided once the device has been reviewed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIOPINCE FULL CORE BIOPSY INSTRUMENT 16G X 15CM
Common Device Name
BIOPINCE
Manufacturer (Section D)
ARGON MEDICAL DEVICES
1445 flat creek rd
athens TX 75751
Manufacturer Contact
elnaz rahman
1445 flat creek rd
athens, TX 75751
9036759321
MDR Report Key14643373
Report Number0001625425-2022-01017
Device Sequence Number5195589
Product Code KNW
UDI-Device Identifier00886333004362
UDI-Public00886333004362
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K904987
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Other
Remedial Action Recall
Type of Report Initial,Followup,Followup
Report Date (Section B) 08/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date05/17/2024
Device Model Number370-1580-01
Device Catalogue Number370-1580-01
Device Lot Number11368354
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/30/2022
Supplement Date Received by Manufacturer05/30/2022
05/30/2022
Initial Report FDA Received Date06/09/2022
Supplement Report FDA Received Date07/11/2022
08/29/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
1625425-12/3/2019-001-R
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient SexUnknown
-
-