| Model Number |
FB-46Q-1 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pancreatitis (4481); Unspecified Hepatic or Biliary Problem (4493)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The suspect device has not been returned to olympus for evaluation.The investigation is in process.The literature article is attached for additional information.Once the investigation has been completed, a supplemental report will be submitted with device evaluation results.
|
| |
|
Event or Problem Description
|
|
Olympus reviewed the following literature titled "usefulness of bile duct biopsy using the new device delivery system endosheather".Diagnosis including benign / malignant differentiation of biliary tract stenosis cases is often made.It is difficult to collect bile duct tissue under erc.Bile duct biopsy is said to be more diagnostic than scraping cytology, and if accurate sniper biopsy is possible, it is expected that the diagnostic ability of bile duct lesions and the accuracy of preoperative mapping biopsy of malignant biliary strictures will be improved.We have developed a device delivery system, endo sheather (es), for the purpose of bile duct biopsy.This device consists of an inner catheter coaxial with the guide wire (gw) and a tapered tip with a small diameter difference, and an outer sheath into which devices up to 5.7 fr can be inserted.Inside the outer sheath is a biopsy forceps for the large intestine.It can be inserted.By using es, quick and accurate sniper biopsy of the target site of biopsy is expected.[type of adverse events / number of patients] pancreatitis 9: mild 6 moderate 1 severe 2, cholangitis 1.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being supplemented to provide additional information from the author and the legal manufacturer's final investigation.New information was added to the following fields: b5, e1, h6, h10.The device history record was unable to be reviewed for this device since the lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the relationship between the device and the adverse event cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Olympus will continue to monitor field performance for this device.
|
| |
|
Event or Problem Description
|
|
Additional information received from the author: in the medical opinion of the author, the olympus devices did not cause or contribute to the adverse events.The author stated there was no malfunction of the olympus device.
|
| |
|