Model Number HX-201UR-135
Medical Device Problem Code Mechanical Jam (2983)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/18/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device is not returned, as such a definitive root cause of the reported complaint cannot be determined at this time.This event is under investigation.A supplemental report will be submitted upon completion of the investigation or upon receiving additional information.
 
Event or Problem Description
As reported for this event by the customer, during a therapeutic polypectomy procedure while attempting to close the site post polypectomy, the device was closed onto the tissue.However, the device clip was not able to release and be deployed.The drive wire inside the handle was buckling out of the handle.The clip had to be removed by force from the tissue and the device removed.The procedure was completed by using device from miroctech brand.There is no harm or adverse impact to the patient.The patient outcome was normal and as expected.Customer request a replacement of the entire batch of the device owned by the customer with devices from other batches.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer¿s final investigation.H4: may 2021 (exact date undetermined).A review of the device history record found no deviations that could have caused or contributed to the reported issue.Based on the investigation results, it is determined that clipping procedure was not completed.Therefore, the clip did not detach from the product.The wire detached from the operating portion while clipping was performed.As a result, the clipping was not completed.A tensile force beyond the resistance strength was applied to the area where the wire was secured in place.This caused the wire to detach from the operating portion.The results of replication testing indicates that the following factor might be the cause of a tensile force beyond the resistance strength was applied to the area where the wire was secured in place.However, the reported phenomenon could not be replicated.Therefore, the exact cause could not be determined.Due to buckling of the area where the clip and the wire was connected, resistance strength was increased.The clip was pressed against an object.This increased a sliding resistance of the slider.The instructions for use (ifu) states the following: should the slightest irregularity and/or breakage of the parts be suspected, withdraw the instrument from the endoscope immediately according to the steps of ¿withdrawing the instrument from the endoscope¿ on page 10.Otherwise, perforation, bleeding, or mucous membrane damage may result.Olympus will continue to monitor field performance of this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE ROTATABLE CLIP FIXING DEVICE
Common Device Name
SINGLE USE ROTATABLE CLIP FIXING DEVICE
Manufacturer (Section D)
OLYMPUS MEDICAL SYSTEMS CORP.
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8 507
JA  192-8507
Manufacturer Contact
kazutaka matsumoto
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8-507
JA   192-8507
426425177
MDR Report Key14655846
Report Number8010047-2022-09841
Device Sequence Number4867623
Product Code PKL
UDI-Device Identifier04953170353123
UDI-Public04953170353123
Combination Product (Y/N)N
Initial Reporter CountryHK
PMA/510(K) Number
K013066
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberHX-201UR-135
Device Lot Number15V
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/18/2022
Supplement Date Received by Manufacturer06/27/2022
Initial Report FDA Received Date06/10/2022
Supplement Report FDA Received Date07/22/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-