ETHICON INC. STFX SYM PDS+ UNI VIO 24IN 1 S/A CTXB; SUTURE, SURGICAL, ABSORBABLE, POLYDIOXANONE
|
Back to Search Results |
|
| Model Number |
SXPP1A306 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Wound Dehiscence (1154)
|
| Date of Event |
05/31/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that a patient underwent an unknown procedure on (b)(6) 2022 and a barbed suture was used for continuous suturing.On postoperative day 6, wound dehiscence occurred.Reoperation was performed on (b)(6) 2022.Current status of the patient at the time of report was being in the hospital.Additional information was requested.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.(b)(4).To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Please provide the patient's demographic information including age, weight, bmi at the time of index procedure.Please confirm date of initial procedure.Please confirm the date of the wound dehiscence.Name of index surgical procedure? the diagnosis and indication for the index surgical procedure? what was the initial approach for the index surgical procedure? (open, laparoscopic or other)? on what tissue was the stratafix suture used? what tissue dehisced? what was the tissue condition (normal, thin, calcified, fragile, diseased)? was the fixation tab seated against the tissue at the initiation of suture use during the index procedure? were two reverse stitches performed across the incision prior to closure? please describe the surgical intervention performed on (b)(6) 2022 for the wound dehiscence including results.Did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation? is it known how the wound dehisced? did the sutures untie, break, or pull out of the tissue? were there any precipitating stress factors that led to the suture untying, breaking or pulling out of the tissue? can you describe the appearance of the stratafix suture during second procedure? what symptoms did the patient experience following the index surgical procedure? onset date? other relevant patient history/concomitant medications? what is the physician¿s opinion as to the etiology of or contributing factors to this event? what is the patient's current status? trade name - irgacare®, active ingredient(s) ¿ triclosan, dosage form ¿ suture/solid/parenteral, strength ¿ = 2360 g/m.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).Date sent to the fda: 6/29/2022 this is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.Additional information: h4, h6 additional information was requested and the following was obtained: the surgery was a pancreaticoduodenectomy.The product was used for fascia.The surgeon commented that the patient's fascia was fragile and the strength of the product was stronger, and that the event occurred due to a combination of various factors.The patient is getting better.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).Date sent to the fda: 8/25/2022.This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information was requested and the following was obtained: the previous additional information received stated ¿for tensile reduction suture, pds was also used on the wound."" please provide further clarification: to relax of tensile and reinforce suture, pds was also used on the wound.Was the pds suture used during the initial procedure? yes.Was there any deficiency with this pds suture? no.Was there any complaint against the pds suture? unknown.Did the pds suture cause or contribute to the wound dehiscence? dr.Think the tissue was torn because the distance from the incision to the suture point was short.Was the pds suture used during the re-operation? unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).Date sent to the fda: 7/22/2022 this is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information was requested and the following was obtained: please provide the patient's demographic information including age, weight, bmi at the time of index procedure.=>female.Please confirm date of initial procedure.=>unknown.Please confirm the date of the wound dehiscence.=>6 days after initial procedure.The re-operation was on (b)(6).Name of index surgical procedure?=>pancreaticoduodenectomy.The diagnosis and indication for the index surgical procedure? =>unknown.What was the initial approach for the index surgical procedure? (open, laparoscopic or other)?=>unknown.On what tissue was the stratafix suture used?=>fascia.What tissue dehisced?=>fascia.What was the tissue condition (normal, thin, calcified, fragile, diseased)?=>dr.Said the fascia was fragile.Was the fixation tab seated against the tissue at the initiation of suture use during the index procedure?=>unknown.Were two reverse stitches performed across the incision prior to closure?=>unknown.Please describe the surgical intervention performed on (b)(6) 2022 for the wound dehiscence including results.=>unknown.Did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation?=>unknown.Is it known how the wound dehisced? did the sutures untie, break, or pull out of the tissue?=>the suture didn't break and the fascia was torn.Were there any precipitating stress factors that led to the suture untying, breaking or pulling out of the tissue?=>unknown.Can you describe the appearance of the stratafix suture during second procedure?=>the suture didn't break and no damage at fixation tab.What symptoms did the patient experience following the index surgical procedure? =>wound dehiscence.Onset date?=>6days after index operation.Other relevant patient history/concomitant medications?=>unknown.What is the physician¿s opinion as to the etiology of or contributing factors to this event?=>at the same time as recognizing that this event was a problem in the usage of the product, various factors such as the patient's fascia was fragile and the product was stronger than the tissue caused dissection.What is the patient's current status?=>recovering in good.Additional information was received.For tensile reduction suture, pds was also used on the wound." attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.The previous additional information received stated ¿for tensile reduction suture, pds was also used on the wound." please provide further clarification: was the pds suture used during the initial procedure? was there any deficiency with this pds suture? was there any complaint against the pds suture? did the pds suture cause or contribute to the wound dehiscence? was the pds suture used during the re-operation?.
|
| |
|