Model Number 220220901
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 05/19/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient underwent a total ankle replacement.Allegedly, the patient may need to undergo a revision surgery for reasons that are not available at the time of this report.
 
Additional Manufacturer Narrative
Based on the available information the device will not be returned therefore an evaluation of the device cannot be performed. a review of the device history is not possible because the lot number was not communicated. should additional information become available, it will be provided on a supplemental report.Device remains implanted in patient.
 
Event or Problem Description
It was reported that the patient underwent a total ankle replacement.Allegedly, the patient may need to undergo a revision surgery for reasons that are not available at the time of this report.
 
Additional Manufacturer Narrative
Correction - h6 device code and h6 results code the reported event could be confirmed, since imaging provided indicates loosening of the tibial component and subsidence of the talar component.Medical affairs was consulted on this case.According to their review of the available information, "the two ct-slices show a clear loosening of the tibial component, indicated by a radiolucent zone around the component, flanked by a sclerotic line.The talar component has subsided." also, "since the ct-images show a clear loosening of the tibial component, and subsidence of the talar component, the patient may complaint about pain and loss of function.Also, the imaging is indicative for a low grade periprosthetic joint infection (the sclerotic line can be response to create a line of a defense thrown up by the bone to prevent the infection from spreading further into the bone).To confirm symptomatic loosening and/or periprosthetic joint infection, clinical information is necessary.This is not available now." more detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.If the device is returned or if any additional information is provided, the investigation will be reassessed.
 
Event or Problem Description
It was reported that the patient underwent a total ankle replacement.Allegedly, the patient may need to undergo a revision surgery for reasons that are not available at the time of this report.
 
Additional Manufacturer Narrative
Correction - d1, d4 (catalog#), gtin, g4, h6 (health impact code, results code) the reported event could be confirmed based on information provided that indicates a gutter debridement was performed and imaging and information from the initial reporter indicated slight subsidence of the tibial tray.Medical affairs was consulted on this case.According to their review of the available information, regarding the tibial tray & stem construct "there is some subsidence without signs of loosening of the prosthesis." also, "since the ct-images show no clear loosening, intraoperative findings and implant retrieval may be helpful to assess the root cause.The implant as such looks in order, assessment of the pe-liner can best be done on the retrieved component." it was noted the tibial construct and talar dome were not explanted as there were not signs of loosening intraoperatively.A gutter debridement was performed with a poly swap.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.If the device is returned or if any additional information is provided, the investigation will be reassessed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INBONE TIB TRAY LEFT SZ 2 LNG
Common Device Name
PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
WRIGHT MEDICAL TECHNOLOGY INC
1023 cherry rd
memphis TN 38117
Manufacturer (Section G)
WRIGHT MEDICAL TECHNOLOGY, INC.
11576 memphis arlington rd
arlington TN 38002
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key14686146
Report Number3010667733-2022-00208
Device Sequence Number4635752
Product Code HSN
UDI-Device Identifier00840420124302
UDI-Public00840420124302
Combination Product (Y/N)N
Initial Reporter StateIN
Initial Reporter CountryUS
PMA/510(K) Number
K100886
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 11/21/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Model Number220220901
Device Catalogue Number220252902
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/19/2022
Supplement Date Received by Manufacturer08/18/2022
10/25/2022
Initial Report FDA Received Date06/14/2022
Supplement Report FDA Received Date09/12/2022
11/21/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
-
-