Model Number SN6AT8
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Corneal Edema (1791); Hyphema (1911); Inflammation (1932); Intraocular Pressure Increased (1937); Itching Sensation (1943); Blurred Vision (2137); Visual Impairment (2138); Dizziness (2194)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Event or Problem Description
A facility representative reported that, following intraocular lens implant procedure, the patent was unable to see and was feeling dizzy.The lens was exchanged in a secondary procedure.Additional information was received that, 1 day post op patient had ocular itching.Vision was very blurry and foggy.Due to increased inflammation difluprednate qday drop started until next appointment.1 week post-op, the patient was having mild corneal bullous change superior which may be causing some visual blurring - will be discontinuing difluprednate as it may be increasing iop and corneal edema.Mild corneal bullous change superior are improved since stopping difluprednate.Iop is improved but borderline od s/p hydrus -inferior microphyphema continued - not much change compared to prior visit.Developed hyphema.Continue prednisolone qid and taper weekly.The lens was exchanged and patient is doing well post-operatively.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACRYSOF IQ TORIC SINGLEPIECE IOL
Common Device Name
LENS, INTRAOCULAR, TORIC OPTICS
Manufacturer (Section D)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key14699056
Report Number1119421-2022-01285
Device Sequence Number5262447
Product Code MJP
UDI-Device Identifier00380652278058
UDI-Public00380652278058
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P930014
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Device Explanted Year2022
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 06/15/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date04/30/2022
Device Model NumberSN6AT8
Device Catalogue NumberSN6AT8U210
Device Lot Number12543095
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/18/2022
Initial Report FDA Received Date06/15/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured05/23/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Other;
Patient Age68 YR