| Model Number |
490103-09 |
| Medical Device Problem Codes |
Defective Device (2588); Unintended Movement (3026)
|
| Health Effect - Clinical Code |
Pneumothorax (2012)
|
| Date of Event |
05/19/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Based on the information provided, the root cause of the customer reported complication cannot be determined.A follow-up mdr will be submitted if additional information is received.Per an intuitive surgical, inc.(isi) senior failure analysis engineer, a system log review cannot be performed because the system logs are not available at this time.No video/images were provided by the customer for review.This complaint is being reported due to the following conclusion: during an ion endoluminal lung biopsy, an ion sheath moved while in use and the needle did not deploy.On a routine chest x-ray, performed an hour post-procedurally, a pneumothorax was identified.As a result, a chest tube was placed to resolve the pneumothorax and the patient was hospitalized for 2-3 days.The cause of the complication is unknown.
|
| |
|
Event or Problem Description
|
|
It was reported that during an ion endoluminal lung biopsy procedure, an ion sheath moved while in use.When the physician deployed the sheath, the needle did not come out when it was pushed down.Upon removing the catheter, the needle was noted to have come to the side of the sheath.The issue did not effect the patient.No injury was reported due to this issue and no additional device failure occurred.Due to the degree of difficulty of the biopsy, the physician stated he used multiple non-ion instruments.The procedure was completed with no additional problems.The patient seemed fine, but on a routine chest x-ray performed an hour post-procedurally, a pneumothorax was identified.As a result, a chest tube was placed to resolve the pneumothorax.The patient was asymptomatic.The physician reported that the patient remained in the hospital from 48 to 72 hours and was discharged home in stable condition and fully recovered from the pneumothorax.The physician explained that the pneumothorax occurred due to the size and position of the lesion which was very close to the pleura.The physician further mentioned that the pneumothorax would have likely occurred via another lung biopsy modality.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information can be found in the following fields: b7, d9, g3, g6, h2, and h3 corrected information can be found in the following fields: d1, d2a, and d4 analysis information can be found in the following fields: h6 and h10 intuitive surgical, inc.(isi) received the biopsy needle involved with this event and failure analysis testing was performed.Failure analysis investigations confirmed the customer reported complaint.The needle had pierced through the sheath approximately 3.7 mm from the distal tip.The sheath measurement of 926mm was in specification.Additional product testing was performed by an advanced failure analysis engineer and additional findings were observed.The heat affected zone was measured to be 4.78mm.The needle tip was observed to be lodged within the sheath.No obvious damage or kinks were observed along the sheath shaft.Some dried blood was visible at the distal sheath.The needle was disassembled.No obvious damage or kinks were observed along the needle shaft.The needle tip was observed to be blunt.Root cause is typically attributed to mishandling/misuse.Blood was observed along the distal 27 mm of the needle measured from the needle tip.No damage was observed to the thumbscrew pin.Needle length was measured to be 1151mm, within the 1150mm +/- 1mm needle length specification.In addition, on (b)(6)2022, additional information was received from the physician: per the physician, the needle did not significantly extend beyond the sheath and this event was not associated with the pneumothorax as the needle did not significantly extend beyond the sheath or into tissue.The physician believed the pneumothorax was caused by biopsies obtained using other non-ion tools (superdimension biopsy forceps and conmed cytology brush) which were assumed to have been used during the procedure.It was reported that the lesion was quite peripheral and that the patient had underlying emphysema, both which the physician felt increased the risk of pneumothorax.
|
| |
|
Event or Problem Description
|
|
Refer to h10/h11 for follow-up information.
|
| |
|