HEARTWARE, INC. HEARTWARE VENTRICULAR ASSIST SYSTEM - PUMP; VENTRICULAR (ASSISST) BYPASS
|
Back to Search Results |
|
Model Number 1104 |
Device Problems
Obstruction of Flow (2423); Pumping Problem (3016)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 06/10/2022 |
Event Type
malfunction
|
Manufacturer Narrative
|
Investigation of this event is pending and a supplemental report will be sent upon its completion.Additional products: heartware ventricular assist system ¿outflow graft model #: 1125 / catalog #: 1125 / unk / serial or lot#: udi #: asku device evaluated: no; no, device evaluation anticipated, but not yet begun; mfg date: unk labeled for single use: yes.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
It was reported that the ventricular assist device (vad) exhibited low flows, and there was a suspected vad inflow or outflow graft obstruction.The vad and outflow graft remain in use.No further patient complications have been reported as a result of this event.
|
|
Manufacturer Narrative
|
A supplemental report is being submitted for a correction to: -g3.Date mfr rec: changed from 10-august-2022 to 19-august-2022 investigation of this event is completed and the file will be closed.If new information is received, the file will be re-opened and a supplemental will be submitted.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Manufacturer Narrative
|
A supplemental report is being submitted for device evaluation and a correction to: -b5.Desc evt problem product event summary: the ventricular assist device (vad) (b)(6) and the associated outflow graft were not returned for evaluation.The reported low flow event was confirmed via review of the controller log files which revealed an intermittent decrease in power consumption and estimated flows on 06-jun-2022, followed by a sudden, sustained decrease in power consumption and estimated flows beginning on 07-jun-2022; however, no alarms were logged within analyzed period.Subsequently, parameters gradually increased, leading to a return to baseline parameters.The reported occlusion event could not be confirmed due to insufficient evidence.Based on the available information, the device may have caused or contributed to the reported event.Based on risk documentation, possible causes of the low flow event may be attributed to multiple factors including but not limited to thrombus at the inflow cannula/outflow graft, constriction at the outflow graft, and/or poor vad filling.Additional products: d1: outflow graft d4: serial#: unknown h3: yes h6: fda method code(s): b17 h6: fda results code(s): c20 h6: fda conclusion code(s): d12 investigation of this event is completed and the file will be closed.If new information is received, the file will be re-opened and a supplemental will be submitted.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
No patient complications have been reported as a result of this event.
|
|