Model Number TGMR373720
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code Aneurysm (1708)
Date of Event 06/15/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
On (b)(6) 2021, this patient underwent endovascular treatment for a thoracic aortic aneurysm and was implanted with two gore® tag® conformable thoracic stent graft with active control system endoprostheses.A tgmr373720 was the most proximal device, having been placed at the left common carotid artery with a snorkel within the left subclavian artery.The exposed stent apicespatient tolerated the procedure.On (b)(6) 2022, the patient underwent reintervention for a proximal type i endoleak (date of onset unknown) and an additional gore® tag® conformable thoracic stent graft with active control system (tgmr373715) was placed proximally.The physician reported that the device was deployed aggressively on target and needed to be retracted due to partial coverage of the innominate artery.The device was retracted successfully with lock wire in place, but it is suspected that it migrated proximally when the lock wire was removed due to stored energy and maneuvering through the previously placed tgmr device.The device was successfully retracted to a satisfactory position with a gore tri-lobe balloon.No injury was noted to the patient and the procedure was successfully completed.At the conclusion of the procedure the exposed stent apices breached the origin of the innominate artery however stent graft itself was well distal to the innominate artery.The patient tolerated the procedure and the endoleak was resolved.The physician reported no enlargement of the aneurysm.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® TAG® CONFORMABLE THORACIC STENT GRAFT WITH ACTIVE CONTROL SYSTEM
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL WOODY SPRINGS B/P
3450 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
laura crawford
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key14755268
Report Number2017233-2022-03027
Device Sequence Number1334362
Product Code MIH
UDI-Device Identifier00733132646821
UDI-Public00733132646821
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
P040043
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 06/21/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date12/12/2023
Device Model NumberTGMR373720
Device Catalogue NumberTGMR373720
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/15/2022
Initial Report FDA Received Date06/21/2022
Date Device Manufactured12/13/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Hospitalization; Required Intervention;
Patient Age59 YR
Patient SexFemale
-
-