As reported to customer relations via complaint form "expired product implanted".Did any section of the device remain inside the patient¿s body? - yes.Please describe the object and how it was retrieved: did the patient experience a delay or require any additional procedure due to this occurrence? no.Please specify delay or any additional procedure(s) and provide details: has the complainant reported any adverse effects on the patient due to this occurrence? has the complainant reported that the product caused or contributed to the adverse effects? please specify adverse effects and provide details.- expired product implanted are images of the device or procedure available? n/a, yes, no.Was this a primary procedure or a recurrent procedure? n/a, primary, recurrent, if this was a recurrent procedure, what procedure had been performed previously? ptcd, ercp, other.If other, please specify.Was a stent previously placed during previous procedures? n/a, yes, no if there was a stent already in place, was the complaint stent placed in the stent that was already in situ? n/a, yes, no.Was the device used percutaneously? n/a, yes, no.Where on the patient was the percutaneous access site? what was the target location for the stent? was the device flushed through both flushing ports before the procedure, as per ifu? n/a, yes, no.Details of the wire guide used (name, diameter, hydrophyllic)? did the patient exhibit difficult anatomy? n/a, tortuous, altered.If altered, please indicate the procedure type (e.G.Cholodochojejunostomy) was resistance encountered when advancing the wire guide to the target location? n/a, yes, no.Was resistance encountered when advancing the delivery system to the target location? n/a, yes, no.How did the physician deal with the resistance encountered? was the delivery system tracked around a tight angle in the patient anatomy? n/a, yes, no.Was the delivery system damaged/kinked/twisted before or during the procedure? n/a, yes, no.If yes, please specify: damaged, kinked, twisted.Please specify when this occurred: was pre-dilation performed ahead of placement of the stent? n/a, yes, no.Did the tip of the delivery system cross the target location? n/a, yes, no.Was the handle pulled towards the hub during deployment? n/a, yes, no.Was the delivery system pushed during deployment? n/a, yes, no.Could the stent be fully deployed at the target location? n/a, yes, no.Was the stent deployed smoothly / without resistance? n/a, yes, no.If no, please detail any difficulty experienced during deployment: was the lesion completely covered by the stent? n/a, yes, no.Was there any device left through the stent post placement? n/a yes, no.If yes, please specify: was the stent fully deployed from the delivery system prior to removal? n/a, yes, no.Was post-dilation performed after the placement of the stent? n/a, yes, no.If the stent is placed across the papilla, what is the length of the portion of the stent in the duodenum? did the patient require any additional procedures as a result of this event? n/a, yes, no.What intervention (if any) was required? was the secondary intervention performed during the same procedure as the device failure or was it scheduled for another day? n/a, same procedure, another day were any other defects (other than the complaint issue) observed on the delivery system (e.G.Kinks) prior to return? n/a, yes, no.If yes, please specify what additional defect(s) were observed and where on the device this was observed?.
|