TERUMO CARDIOVASCULAR SYSTEMS CORPORATION ADVANCED PERFUSION SYSTEM 1; CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS-ADVANCED PERFUSION SYSTEM 1 Back to Search Results
Model Number 6382
Medical Device Problem Code Device Alarm System (1012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/02/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Per data log analysis, the system was powered up on (b)(6) 2022 and the flow module had sensor serial number (b)(4) attached.A perfusion screen was opened at 07:09:26 am.The flow sensor was disconnected and a different sensor was attached at 07:47:44 am (serial number (b)(4)).Starting at 07:48:21 am, many backflow alarms occurred.There was no way to tell from the log if actual backflow was occurring.The flow sensor was disconnected again and the original flow sensor serial number (b)(4) was connected at 07:52:05 am.The field service representative (fsr) verified the complaint.The flow readings would fluctuate during forward flow as reported.When the centrifugal control unit was stopped and at zero flow, the fluctuations still persisted and went positive and negative flow causing the reported intermittent back flow alarms.The fsr replaced the flow sensor.The unit operated to the manufacturer's specifications.During laboratory evaluation, the product surveillance technician (pst) was unable to test the sensor due to a damaged pin number six on the connector.This complaint is related to (b)(4) / mfr# 1828100-2022-00246.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Event or Problem Description
It was reported that during priming of the device for a cardiopulmonary bypass (cpb) procedure, the flow sensor had intermittent back flow alarms.The surgical procedure was completed successfully.There was no delay, no blood loss, nor adverse consequences to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVANCED PERFUSION SYSTEM 1
Common Device Name
CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS-ADVANCED PERFUSION SYSTEM 1
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
Manufacturer (Section G)
SAME
Manufacturer Contact
douglas patton
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key14835795
Report Number1828100-2022-00247
Device Sequence Number14045231
Product Code DTQ
UDI-Device Identifier00886799000083
UDI-Public(01)00886799000083(11)210927
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K172220
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 06/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number6382
Device Catalogue Number6382
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/07/2022
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/02/2022
Initial Report FDA Received Date06/27/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/27/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-