| Catalog Number |
293001-001 |
| Medical Device Problem Codes |
Electrical /Electronic Property Problem (1198); Battery Problem (2885)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
06/01/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
The customer, a syncardia certified hospital, reported that when the companion external battery was installed in the companion 2 driver, there was an error symbol over the battery icon on main driver display.The customer also reported the companion external battery gauge lights did not work.
|
| |
|
Additional Manufacturer Narrative
|
|
The companion external battery will be returned to syncardia for evaluation.The results will be provided in a follow-up mdr.
|
| |
|
Additional Manufacturer Narrative
|
|
The customer confirmed that they have lost the companion external battery pack.Syncardia is closing this file.(b)(4) follow-up report 1.
|
| |
|
Additional Manufacturer Narrative
|
|
Companion external battery pack was located by customer and returned to manufacturer for investigation.Device history record (dhr) review confirmed that companion external battery s/n (b)(6) was serviced and passed all functional testing prior to being released to finished goods.Alarm history and data file review found no alarms or failures.Visual inspection of external components found no abnormalities.Battery passed all areas of functional testing for acceptance at incoming inspection.Additional testing included installation into an onsite test companion 2 driver.Upon installation, battery gas gauge led started flashing indicating battery was charging.The battery was allowed to charge to capacity and driver was removed from ac power to run on the battery exclusively.Driver ran successfully on battery for 25 minutes indicating battery was functioning as intended.Complaint could not be replicated.Failure investigation for this complaint could not confirm the reported issue.The customer complaint was not replicated; the root cause of the reported inability of the driver to function with this specific battery, was unable to be determined.Failure investigation identified no test failures or damage that could have contributed to the complaint.The battery functioned as intended and no evidence of a malfunction was found.Companion 2 driver in use at the time was not returned for investigation, however, it was reported that the driver functioned normally with a different battery.Battery was not in patient use at time of complaint.This issue will be monitored and trended as part of the customer complaint process.Syncardia has completed its evaluation and is closing this file.If new or additional information is received in the future, syncardia will file a follow-up mdr.
|
| |
|
Event or Problem Description
|
|
The customer, a syncardia certified hospital, reported that when the companion external battery was installed in the companion 2 driver, there was an error symbol over the battery icon on main driver display.The customer also reported the companion external battery gauge lights did not work.
|
| |
|