It is reported in the literature titled: "single balloon enteroscopy: is it feasible? patients experienced adverse events after procedures using olympus devices.Case with patient identifier (b)(6) reports obcu.Case with patient identifier (b)(6) reports st-sb1.Case with patient identifier (b)(6) reports sif-q260.Background/aims.Currently, two endoscopic modalities are used to investigate the small intestine.Capsule endoscopy (ce) has been used mainly as a screening tool for evaluating obscure gastrointestinal bleeding.However, ce also has several disadvantages, such as inadequate manipulation in the lumen, the inability to take tissue samples, and the inability to treat intestinal strictures.Double-balloon enteroscopy (dbe) and its insertion technique were first published by yamamoto and coworkers in 2001.Although dbe is more invasive than ce, dbe is clinically a very useful tool not only for diagnosis, but also for endoscopic therapy in the small intestine.5-15 although the method for dbe insertion has already been established, there are a few problems in terms of preparation and insertion for dbe as compared with conventional endoscopies.For example, during preparation, attaching the balloon with a rubber band to the tip of the endoscope is always necessary.During examination, the endoscopist must also handle two kinds of balloon systems for efficient insertion.Recently, we developed a novel single balloon enteroscopy (sbe) system and its insertion technique for examination of the small intestine.The sbe system consists of a dedicated endoscope without a balloon, a sliding tube with a balloon, and an air controller to inflate or deflate the balloon of the overtube.This study was designed to evaluate whether sbe is feasible and useful for examination of the small intestine.¿methods.We have performed 80 sbe procedures (39 using the oral route and 41 using the anal route) on 41 patients during an 18-month period (january 2006 to july 2007).The clinical characteristics of these patients are shown in table 1.The reasons for the sbe examination were obscure gastrointestinal bleeding (n =12), crohn¿s disease (n =16), chronic abdominal pain (n= 5), chronic diarrhea (n =3), and suspected small-bowel tumors (n =5).The mean procedure time for the oral route was 62.3 minutes (range 39 to 118 minutes).The mean number of shortening procedures was 9.2 (range 3 to 16).Observation of the deep small intestine by the oral route was possible in 27 of 39 procedures.The deep small intestine could not be observed during the other 12 procedures due to intestinal adhesions (n 6), intestinal strictures due to crohn¿s lesions (n= 4), and intestinal tumors (n= 2).Results.All of the crohn¿s patients (n =16) demonstrated ulcers or scar lesions in the ileocecal region.Among the 12 patients with suspected mid-gastrointestinal bleeding, new diagnoses following sbe were made in 4 patients (1 jejunal adenocarcinoma, 1 nsaid enteropathy, and 2 angiodysplasia).There were no endoscopic findings among 5 patients with chronic abdominal pain and 3 with chronic diarrhea.In the 5 patients with abdominal tumors, 3 patients with intestinal lymphomas were diagnosed by biopsy specimens taken by sbe.Endoscopic therapies using sbe were performed in 6 patients with crohn¿s disease.A total of 15 lesions caused by intestinal stricture were dilated using the cre balloon system (usa, 12-16.5 mm, 2 minutes).The 2 patients with angiodysplasia received endoscopic hemostasis with a heat probe.Conclusions.We conclude that an enteroscope with even a single balloon can safely and effectively inspect the deep small intestine.Therefore, sbe is a feasible diagnostic and therapeutic tool in the small intestine in addition to dbe.The sbe procedure was safely completed in 38 patients.Of the first 10 cases that were performed using the oral route in the supine position, 1 patient with crohn¿s disease complained of chills, and had a 38.5°c body temperature on the night after receiving sbe.Although aspiration pneumonia was suspected, there were no abnormal findings on chest radiograph, and the body temperature normalized on the next day.After this patient¿s experience, all of the subsequent patients received sbe using the oral route in the prone position.One patient with crohn¿s disease had a complication during anal route insertion when the tip of the scope pressed against a longitudinal ulcer scar during the insertion of the overtube, creating a mucosal tear.The tear was closed with 4 clips.The patient recovered after antibiotics administration for 2 days without food.The crohn¿s patient who received balloon dilation (16.5 mm, 3 minutes) for a stricture of the ileocecal valve complained of severe abdominal pain and had a 39.5°c body temperature after the sbe procedure.An abdominal ct revealed transmural wall thickening at the terminal ileum and localized ascites.With a diagnosis of localized peritonitis, the patient recovered after a 2-week course of antibiotics.There is no report of any olympus device malfunction in any procedure described in this study.
|