• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ABBOTT GMBH CALCIUM; AZO DYE, CALCIUM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT GMBH CALCIUM; AZO DYE, CALCIUM Back to Search Results
Model Number 3L79-22
Medical Device Problem Code Low Test Results (2458)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/27/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Event or Problem Description
The customer observed a falsely depressed calcium result generated on the architect c16000 processing module for one sample.Results provided: (customer range 8.4-10.2 mg/dl).Sid (b)(6) initial result 5.9 mg/dl, repeated on another instrument 9.4 mg/dl no impact to patient management was reported.
 
Additional Manufacturer Narrative
The complaint investigation for falsely depressed calcium results included a review of data and information provided by the customer, search for similar complaints, ticket trending review, labeling review, and device history record review.Return testing was not completed as returns were not available.Trending review by did not identify any trends for the issue for the product.Device history record review did not identify any non-conformances or deviations with list number 03l79 and the complaint issue.Labeling was reviewed and sufficiently addresses the customer's issue.As part of troubleshooting, the samples was retested on another analyzer and gave higher normal results.Additionally, a clog in the high concentration waste line was discovered, indicating a possible pre-analytical condition may have caused the initial low result.Based on our investigation, no systemic issue or deficiency with the calcium assay for unknown lot was identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CALCIUM
Common Device Name
AZO DYE, CALCIUM
Manufacturer (Section D)
ABBOTT GMBH
max-planck-ring 2
wiesbaden 65205
GM  65205
Manufacturer (Section G)
ABBOTT GMBH
max-planck-ring 2
wiesbaden 65205
GM   65205
Manufacturer Contact
siobhan wright
lisnamuck
post market surveillance
longford N39 E-932
EI   N39 E932
433331157
MDR Report Key14850597
Report Number3002809144-2022-00225
Device Sequence Number16739177
Product Code CJY
UDI-Device Identifier00380740161491
UDI-Public00380740161491
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
K062855
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number3L79-22
Device Catalogue Number03L79-22
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 06/27/2022
Supplement Date Received by Manufacturer08/29/2022
Initial Report FDA Received Date06/29/2022
Supplement Report FDA Received Date08/29/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ARC C16K REFURB-SEKAT, 03L77-97, (B)(6) ; ARC C16K REFURB-SEKAT, 03L77-97, (B)(6)
Patient SexUnknown
-
-