MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION INTERLOCK-35; DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION INTERLOCK-35; DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION Back to Search Results
Model Number 83787
Medical Device Problem Codes Entrapment of Device (1212); Difficult to Remove (1528); Device-Device Incompatibility (2919)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/09/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the coil has come out of the catheter.The target lesion was located in the moderately tortuous and non-calcified internal iliac artery.A 8mm x 20cm.035 interlock cube embolics was selected for use.During delivery of the product, a gutter was created by breaking through the wall of the catheter instead of the tip and the coil has come out of the catheter.The entire catheter was removed, however, two-thirds of the coil protruded from the tip.The procedure was completed with a different device.There were no complications reported.
 
Additional Manufacturer Narrative
Device evaluated by manufacturer: only the main coil was returned analysis.The main coil was kinked and stretched.No more damages were found.
 
Event or Problem Description
It was reported that the coil has come out of the catheter.The target lesion was located in the moderately tortuous and non-calcified internal iliac artery.A 8mm x 20cm.035 interlock cube embolics was selected for use.During delivery of the product, a gutter was created by breaking through the wall of the catheter instead of the tip and the coil has come out of the catheter.The entire catheter was removed, however, two-thirds of the coil protruded from the tip.The procedure was completed with a different device.There were no complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTERLOCK-35
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORK LIMITED
model farm road
cork
EI  
Manufacturer Contact
jay johnson
4100 hamline ave n
arden hills, MN 55112
6515810888
MDR Report Key14880660
Report Number2134265-2022-07244
Device Sequence Number5040027
Product Code KRD
UDI-Device Identifier08714729793052
UDI-Public08714729793052
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K133208
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/25/2023
Device Model Number83787
Device Catalogue Number83787
Device Lot Number0025269719
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 06/09/2022
Supplement Date Received by Manufacturer07/19/2022
Initial Report FDA Received Date06/30/2022
Supplement Report FDA Received Date08/12/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/26/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
GUIDE CATHETER-4FR IMPRESS; GUIDE CATHETER-4FR IMPRESS; GUIDEWIRE-RADIFOCUS; GUIDEWIRE-RADIFOCUS
Patient SexUnknown
-
-