| Model Number |
ZCU450 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Visual Disturbances (2140)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that the intraocular lens (iol), model zcu450 with 15.0 diopter power, was implanted in the patient¿s right eye.The iol was explanted in a separate surgical procedure and replaced with a zcu150 model lens with 15.5 diopter power due to visual impairment that was first identified during post-operative examination.It was reported that the patient was temporarily impaired.Account indicated that there were no complications, such as capsular tear, no incision enlargement, no serious patient injury, no unplanned suture(s), and no vitrectomy during the iol explant procedure.Patient outcome post-lens exchange is unknown.It is also unknown if the patient is still temporarily impaired post-lens exchange.No further information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: patient weight: unknown as information was asked but not provided.Date of event: unknown as information was not provided; the best estimate date is between 31-mar-2022 and 15-jun-2022.The device was not returned for evaluation; therefore, a failure analysis of the complaint device cannot be completed.A review of the device history record, complaint trending, and risk documentation for this device will be performed.Upon completion of the review, if there is any further relevant information a supplemental medwatch will be filed.Attempts were made to contact the customer account requesting additional information regarding the complaint; however, to date no response has been received.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
Product investigation was completed, and the following fields were updated accordingly: section d-9: device available for evaluation: yes.Section d-9: date returned to manufacturer: 18-aug-2022.Section h-3: device returned to manufacturer: yes.Device evaluation: the complaint lens was received in an unknown solution inside a specimen cup.Visual inspection under magnification revealed the lens was returned cut in half.No defects that could contribute to visual issues were observed.No additional defects were observed.Complaint issue ¿visual disturbance¿ was not confirmed.The other observed issues during the product evaluation could not be confirmed to be related to a manufacturing or design issue.Therefore, there is no indication of a product deficiency or product malfunction.Conclusion: based on the investigation results, there is no indication of a product malfunction or product quality deficiency.The reported issue was not verified.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Search Alerts/Recalls
|