The v.A.C.® dressing lot number was not provided and the product was not returned, therefore a device history record review and device evaluation could not be completed.Based on the information provided, kci cannot determine when the foreign material alleged to be v.A.C.® dressing was placed in the wound.The foreign material was not returned to kci for identification; therefore, kci is unable to confirm its identity.The nurse indicated the adhered v.A.C.® dressing was due to an error in wound care by the previous nurse; therefore, this event is being reported due to potential use error.Device labeling, available in print and online, states: warning: never leave a v.A.C.® dressing in place without active v.A.C.® therapy for more than two hours.If therapy is off for more than two hours, remove the old dressing and irrigate the wound.Either apply a new v.A.C.® dressing from an unopened sterile package and restart v.A.C.® therapy; or apply an alternate dressing, such as a wet to moist gauze, as approved during times of extreme need, by treating physician.Dressing changes wounds being treated with the v.A.C.® therapy system should be monitored on a regular basis.In a monitored, non-infected wound, v.A.C.® dressings should be changed every 48-72 hours, but no less than 3 times a week, with frequency adjusted by the clinician as appropriate.Infected wounds must be monitored often and very closely.For these wounds, dressings may need to be changed more often than 48-72 hours; the dressing changing intervals should be based on a continuing evaluation of the wound condition and the patient's clinical presentation, rather than a fixed schedule.Foam placement: always use v.A.C.® dressings from sterile packages that have not been opened or damaged.Do not place any foam dressing into blind / unexplored tunnels.The v.A.C.® whitefoam¿ dressing may be more appropriate for use with explored tunnels.Do not force foam dressings into any area of the wound, as this may damage tissue, alter the delivery of negative pressure or hinder exudate and foam removal.Always count the total number of pieces of foam used in the wound.Document the foam quantity and dressing change date on the drape or foam quantity label if available, and in the patient's chart.Foam removal: v.A.C.® foam dressings are not bioabsorbable.Always count the total number of pieces of foam removed from the wound and ensure the same number of foam pieces are removed as were placed.Foam left in the wound for greater that the recommended time period may foster ingrowth of tissue into the foam, create difficulty in removing the foam from the wound or lead to infection or other adverse events.If dressing adheres to wound consider introducing sterile water or normal saline into the dressing, waiting 15 - 30 minutes, then gently removing the dressing from the wound.Regardless of treatment modality, disruption of the new granulation tissue during any dressing change may result in bleeding at the wound site.Minor bleeding may be observed and considered expected.However, patients with increased risk of bleeding, as described on page 8, have a potential for more serious bleeding from the wound site.As a precautionary step, consider using v.A.C.® whitefoam¿ dressings or nonadherent material underneath the v.A.C.® granufoam¿ dressings to help minimize the potential for bleeding at dressing removal in these patients.
|
On (b)(6) 2022, the following information was provided to kci by the patient: on (b)(6) 2022, there was foreign material alleged to be v.A.C.® dressing in the wound when the activ.A.C.¿ ion progress¿ remote therapy monitoring system was removed.The patient followed-up with the physician the following day to have the foreign material removed.The home health nurse reapplied the activ.A.C.¿ ion progress¿ remote therapy monitoring system on (b)(6) 2022.On (b)(6) 2022, the following information was provided to kci by the nurse: the adhered v.A.C.® dressing was found during the dressing change on (b)(6) 2022.It was due to error in wound care by a different nurse during a prior dressing change, date unknown.The patient was seen on (b)(6) 2022 in office by the physician and debridement was performed to remove the adhered v.A.C.® dressing.No additional information was provided.The v.A.C.® dressing lot number was not provided, and the product was not returned; therefore, a device history record review and device evaluation could not be performed.
|