Model Number SA87G
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 05/12/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product complaint#: (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.The following information was requested, but unavailable: was there any adverse consequence associated with the patient? was there any change in the patient¿s post-operative care due to the prolonged procedure? were there any unexpected outcomes or complications as a result of the prolonged surgery time? how long (in minutes) did the surgery prolong? please confirm if there was postoperative bleeding: was there any adverse consequence associated with the patient? all answers above are unobtainable.Once there is any update, we will update the information.Mfr retained sample investigation summary: actual customer complaint sample or same batch representative sample are not returned.Same batch manufacturer retained sample evaluated for [appearance] and [tensile strength] per current version of sop-06-14 and no issue found, detail testing data please refers to investigation plan.Dhr reviewed and no issue found.The root cause of this complaint can¿t be determined, this complaint data will be kept for trend analysis.A manufacturing record evaluation was performed for the finished device lot, and no non-conformance's were identified.Events reported via: 2210968-2022-05155 and 2210968-2022-05157.
 
Event or Problem Description
It was reported that a patient underwent a hysterectomy procedure on (b)(6) 2022 and suture was used.During the procedure, it was reported that suture broke during sewing vaginal wall in surgery.The procedure was vaginal hysterectomy + modified anterior pelvic floor suspension + middle urethral suspension + paravaginal repair + excision of posterior vaginal wall vegetation.Changed another two to continue the surgery, the same problem happened.Changed another one to complete the surgery.No adverse patient consequences were reported.Additional information was requested.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SILK BLK 10X30IN 1 NON NDL
Common Device Name
SUTURE, NONABSORBABLE, SILK
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
9083863534
MDR Report Key14940685
Report Number2210968-2022-05156
Device Sequence Number12351789
Product Code GAP
UDI-Device Identifier10705031050303
UDI-Public10705031050303
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K946173
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 07/06/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberSA87G
Device Catalogue NumberSA87G
Device Lot NumberRL2AL
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/13/2022
Initial Report FDA Received Date07/06/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/10/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age66 YR
Patient SexFemale
-
-