ETHICON INC. VCL+ VIO 27IN 0 S/A CT; SUTURE, ABSORBABLE, SYNTHETIC Back to Search Results
Model Number VCP352H
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/01/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that a patient underwent an unknown procedure in 2022 and suture was used.During the procedure, the incident happened during the closing of second layer of uterus.The scrub nurse noticed the needle is incomplete (no tip).Surgeon was informed directly.They looked for the tip in the patient abdomen cavity or table and floor, where to be found, and no needle found.No adverse patient consequences were reported.Additional information was requested.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).(b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was requested, and the following was obtained via: were x-rays taken to locate the needle piece(s)? yes.Was there any additional tissue damage as a result of searching for the needle piece? no.Trade name - irgacare®.Active ingredient(s) ¿ triclosan.Dosage form ¿ suture/solid/parenteral.Strength ¿ = 275 g/m.Events reported via: 2210968-2022-05342.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Date sent to the fda: 8/23/2022.This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.H6 component code: c22 - photo analysis.H3 investigational summary ¿ photo analysis: this is an analysis of three photos submitted to ethicon for evaluation.During visual analysis the following was observed: the photo shows two pins of product code vcp352h.The needles were observed with use, bodily fluids, marks, distorted in the original curvature and broken at the tip of one of the needles.Based on the pi-16553257013726875 review, the event described breakage needle confirmed, however, no conclusion or root cause could be determined.Please refer to the device analysis for full analysis details and conclusion.As part of the ethicon¿s quality process, all devices are manufactured, inspected, and released to approved specifications.We value your assistance in providing us an opportunity to evaluate the reported event as all information reported to our company is critical to our continuous improvement efforts.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of post market surveillance.Trade name - irgacare®.Active ingredient(s) ¿ triclosan.Dosage form ¿ suture/solid/parenteral.Strength ¿ = 275 g/m.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Date sent to the fda: 8/8/2022.This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.H3 investigational summary: the product was returned for evaluation.Visual inspection and functional testing were conducted on the returned device.A scanning electron microscope was used to examine the fracture surfaces and surrounding area of the needle.A fracture was observed at the tip of the needle.One side of the needle was received, the mating fracture surface was not provided for this evaluation.The second needle was bent, but not fractured, therefor no additional analysis was performed.The fracture surfaces were examined in multiple locations to determine the fracture mode.The fracture surface contained microvoid coalescence, evidence of a ductile fracture mode.Mechanical damage in the form of indents and scratches were observed coincidental to the fracture.Mechanical damage observed coincidental to the fracture provides additional evidence that the failure was induced by mechanical deformation leading to ductile overload.This was a ductile fracture.The manufacturing records were reviewed and the manufacturing criteria were met prior to the release of this batch.Additional complaint information monitoring for potential safety signals is conducted through complaint trending as part of post market surveillance.Trade name - irgacare®; active ingredient(s) ¿ triclosan; dosage form ¿ suture/solid/parenteral; strength ¿ = 275 g/m.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VCL+ VIO 27IN 0 S/A CT
Common Device Name
SUTURE, ABSORBABLE, SYNTHETIC
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.-GMBH
robert- koch strass1
norderstedt
GM  
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
9083863534
MDR Report Key14983412
Report Number2210968-2022-05341
Device Sequence Number5022236
Product Code GAM
UDI-Device Identifier10705031052635
UDI-Public10705031052635
Combination Product (Y/N)Y
Initial Reporter CountrySA
PMA/510(K) Number
K132580
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 09/28/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/31/2024
Device Model NumberVCP352H
Device Catalogue NumberVCP352H
Device Lot NumberRBBCKKW0
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/14/2022
Supplement Date Received by Manufacturer07/22/2022
08/10/2022
09/28/2022
Initial Report FDA Received Date07/11/2022
Supplement Report FDA Received Date08/08/2022
08/23/2022
09/28/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/15/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-