| Model Number |
EUP2010X |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Vascular Dissection (3160)
|
| Date of Event |
05/09/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
An attempt was made to use a nc euphora balloon catheter to treat a lesion located in the left circumflex artery.The lesion was pre-dilated using a 2.5 x 6mm euphora rx balloon catheter and was inflated at 14atm.A 2.5 x 18mm non-mdt stent was then implanted into the lesion.The nc euphora device was inserted into the non-mdt stent.After the balloon was placed inside the stent it was inflated at 6atm but either the balloon did not inflate or it could not be seen under fluoro.The technician pulled negative on the inflation device and re-inflated the balloon at 12atm and this time the balloon was seen to be inflated under fluoro.The balloon was inflated for a directed time and then the inflation device was pulled negative to deflate the balloon.It was reported that the balloon would not deflate and was still inside the patient.Multiple attempts were made to deflate the balloon with different devices including, balloons, snares, wires, catheters, micro-catheters and guides, but all attempts were unsuccessful.It was also reported that at some point in time the artery dissected and the shaft of the nc euphora device broke off.After the shaft broke the balloon remained inflated and part of the catheter was left in the patient as well as the inflated balloon.A number of attempts were made to puncture the balloon using two euphora ptca balloon catheters, snare the balloon using gooseneck microsnares and remove the balloon, but none were successful.Code blue was called following intervention attempts and a heart pump device was implanted.The procedure lasted approximately 9 hours until the procedure was stopped and the patient was sent to the intensive unit care (icu) with the balloon still inflated in the patient¿s artery.The patient was a non surgical candidate.The balloon remains in the patient.The patient deceased the next day.The cause of death was related to the nc euphora balloon which was unable to be deflated.It was subsequently reported that the device was successfully retrieved from the patient during autopsy.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: prior to the procedure the patient presented to hospital with worsening exertional dyspnea and chest pain, and was on max medical therapy as tolerated.During the nc euphora device preparation there were no issues experienced with the removal of the stylette and the balloon protector.The balloon was inspected prior to threading onto the guide wire into the vasculature, to ensure that there was no damage to the device.After 6 atm, the technician pulled negative on the inflation device and then re-inflated the balloon to 12atm, and this time the balloon was seen to be inflated under fluoro.The dissection was due to attempts to capture/deflate the nc balloon and/or to crush stent.Code blue was called following intervention attempts as the patient became hypotensive and had severe chest pain.The patient was intubated and a heart pump device was implanted.There was no malfunctions experienced with the other medtronic devices used during the procedure.The autopsy procedure was only used to remove the device and did not share the cause of death.A 1:1 concentration of contrast/saline was used during the procedure.Patient weight provided.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|