ABBOTT VASCULAR GRAFTMASTER RX CORONARY STENT GRAFT SYSTEM; CORONARY STENT DELIVERY SYSTEM Back to Search Results
Model Number 1012581-19
Medical Device Problem Codes Patient-Device Incompatibility (2682); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Foreign Body In Patient (2687); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/21/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a perforation occurred during an intervention to the left anterior descending (lad) coronary artery.A 3.5x19mm graftmaster covered stent was advanced and implanted, but failed to seal the perforation.Next a 4x19mm graftmaster covered stent was implanted, but the perforation remained unsealed.It is unknown if the perforation was ever sealed; however, sometime after the full intervention, the patient experienced pulseless electrical activity (pea arrest) and could not be resuscitated.The patient died.Per the physician, the graftmaster stents did not cause or contribute to complications or adverse events.There was no additional information provided.
 
Additional Manufacturer Narrative
The stent remains implanted.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.The 4.00x19mm graftmaster stent is filed under a separate medwatch report number.
 
Event or Problem Description
Subsequent to the initial filed reports, the following information was received: it was reported that the patient sustained a pulseless electrical activity arrest (pea) with acute closure of the left main (lm) and left anterior descending (lad) artery after the placement of unspecified stents.The patient was receiving active cardiopulmonary resuscitation (cpr) throughout the following hour which limited the ability to image the vessel and treat the patient.The guiding catheter (gc) was in the left main (lm) with a guide wire (gw) in the lad when the patient went into cardiac arrest.The image intensifier (cath lab camera) had to be move out to allow staff to perform cpr.The camera was only able to be repositioned for short sequences to try to stabilize the patient.When the camera was moved back into position for a few seconds, the guiding catheter and wire appeared to be in the same position but had unknowingly dropped out of the artery and the wire prolapsed into the left ventricle (lv).Contrast injections demonstrated extravasation of contrast in the cusp near the valve leading to conclude that there was a left main perforation.The guide wire was coursing under the anterior surface of the lv directly below and along the same course of the epicardial lad, leading to the conclusion the gw was in the lad when it was not.The 3.5x19mm graftmaster covered stent was placed over the wire with the belief it was in the left main and deployed.More camera removal and cpr followed.When reimaging was done, the graftmaster could not be located and a 4x19mm graftmaster was deployed.Ultrasound demonstrated no pericardial effusion leading us to perform longer imaging runs that allowed us to identify that the graftmaster stents had migrated along the wire and were in the lv.The gc was eventually repositioned during cpr cycles, the artery was eventually re-cannulated and successfully stented gaining reperfusion.All this was done in short segments of time as he received cpr for approximately one hour without recovery of spontaneous circulation (rosc).No meaningful sustained rhythm was ever achieved, and the patient was pronounced dead in the cath lab.Had the patient survived, the graftmaster stents would have been retrieved from the lv percutaneously.It is the physician¿s opinion that the graftmaster stents did not ¿seal the perforation¿ as it was eventually determined there was no perforation and the guide wire was dislodged by cpr into the lv.The use of graftmaster stents did not help nor hurt the patient in any way and had no effect on the patient outcome.
 
Additional Manufacturer Narrative
The device was not returned for evaluation.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.A conclusive cause for the reported patient effect, and the relationship to the product, if any, cannot be determined; however, the foreign body in patient appears to be related to the operational context of the procedure.Based on the information reviewed, there is no indication of a product quality issue with respect to manufacture, design, or labeling.B1 - adverse event/product problem: product problem - removed.B2 - outcomes attributed to ae required intervention - removed.D6a.Implant date - stent was not implanted.H6: health effect - clinical code 4582 -removed.H6: health effect - impact code 4641 - removed.H6: medical device problem code 2682 - removed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GRAFTMASTER RX CORONARY STENT GRAFT SYSTEM
Common Device Name
CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key15021866
Report Number2024168-2022-07727
Device Sequence Number6856050
Product Code MAF
UDI-Device Identifier08717648176401
UDI-Public08717648176401
Combination Product (Y/N)N
Initial Reporter StateOK
Initial Reporter CountryUS
PMA/510(K) Number
H000001
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/19/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/31/2022
Device Model Number1012581-19
Device Catalogue Number1012581-19
Device Lot Number0112741
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 06/24/2022
Supplement Date Received by Manufacturer07/28/2022
Initial Report FDA Received Date07/14/2022
Supplement Report FDA Received Date08/19/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/27/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient Age64 YR
Patient SexMale
-
-