|
|
| Model Number |
04.211.018 |
| Medical Device Problem Code |
Migration (4003)
|
| Health Effect - Clinical Code |
Failure of Implant (1924)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Device report from synthes reports an event in japan as follows: it was reported that on (b)(6) 2022, the patient underwent the open reduction internal fixation surgery for the distal clavicular of right fracture with the plate and screws in question.The surgery was completed successfully without any surgical delay.On (b)(6) 2022, several malfunctions were observed in outpatient follow-up examination as follows.The right clavicle has obvious tenting.It was confirmed by computed radiography (cr) image that two screws inserted into the distal bone fragment were broken.Those lot or size could not be identified.Two other screws inserted into the distal bone has backed out.The plate has been dislodged.The patient has no subjective symptom.A revision surgery will occur but it is not known if it has been completed.This is report 8 of 9 for (b)(4).This report is for a locking screw.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Date of event: it is unknown when devices malfunctioned; some time between (b)(6) 2022 and (b)(6) 2022.Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.(once explanted).Device is not distributed in the united states, but is similar to device marketed in the usa.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: a manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.Part #: 04.211.018ts.Lot #: 8l96646.Manufacturing site: werk selzach.Supplier: früh verpackungstechnik ag.Release to warehouse date: 11 jan 2022.Expiration date:01 jan 2027.Part #: 04.211.018.Lot #: 570p516.Manufacturing site: werk selzach.Supplier: synthes usa hq, inc.Release to warehouse date: 13 dec 2021.Expiration date: n/a.The product was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that there was no damage or defects with the va lockscr ã¸2.7 he 2.4 self-tap l18 tan.The screw presents some signs of wear most likely created during removal process of the implant.Migration condition cannot be confirmed since x-ray evidence was not provided.A dimensional inspection for the va lockscr ã¸2.7 he 2.4 self-tap l18 tan was unable to be performed due to complex geometry of the device.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was not confirmed as the va lockscr ã¸2.7 he 2.4 self-tap l18 tan was found to have no damage or defects.No definitive root cause could be determined.There was no indication that a design or manufacturing issue contributed to the complaint.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Search Alerts/Recalls
|
|
|