Model Number 20012S
Medical Device Problem Codes Material Separation (1562); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/21/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Medtronic received information that prior to use of a dlp aortic root cannula with vent line, the customer reported that it was impossible to unscrew the metal conductor in the proximal part, the customer stated that "it is soldered".The cardiac surgeon tried to carry out this procedure with clamps, so there are mechanical damages on the cannula.The attempt was unsuccessful.The cannula was replaced to complete the procedure.There was no patient involvement so no adverse effect occurred.Medtronic received additional information that the cannula was not heated or cooled prior to use.
 
Additional Manufacturer Narrative
Conclusion: after investigation the complaint is confirmed for a bonded luer connector resulting in the user being unable to remove the introducer needle based on the photos provided by the customer.This complaint is the result of a manufacturing issue, as the components were inadvertently bonded during assembly.The instructions for use do instruct the user to perform the following steps prior to insertion: "check the luer fitting connection by first holding the female luer adapter of the cannula and twisting the male luer of the needle assembly counter-clockwise.Withdraw the introducer from the cannula completely to ensure that the introducer can be withdrawn smoothly.Inspect the point on the introducer to ensure that the point has not been inadvertently bent or damaged.Carefully replace the introducer in the cannula, then re-engage the male luer and lock it into place by holding the female luer of the cannula and twisting the male luer of the needle assembly clockwise".There were no adverse patient effects because of this occurrence.Trends for issues with this device are monitored.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AORTIC ROOT ANTEGRADE ANTEGRADE CANNULA
Common Device Name
CATHETER, CANNULA AND TUBING, VASCULAR, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
PERFUSION SYSTEMS
7611 northland dr
brooklyn park MN 55428
Manufacturer (Section G)
PERFUSION SYSTEMS
7611 northland dr
brooklyn park MN 55428
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key15049959
Report Number2184009-2022-00171
Device Sequence Number5489216
Product Code DWF
UDI-Device Identifier00613994495525
UDI-Public00613994495525
Combination Product (Y/N)N
Initial Reporter CountryRS
PMA/510(K) Number
K810548
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/29/2023
Device Model Number20012S
Device Catalogue Number20012S
Device Lot Number2020120962
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/21/2022
Supplement Date Received by Manufacturer07/28/2022
Initial Report FDA Received Date07/19/2022
Supplement Report FDA Received Date08/25/2022
Date Device Manufactured02/12/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-