Olympus reviewed the following literature titled, "conventional transbronchial needle aspiration versus endobronchial ultrasound-guided transbronchial needle aspiration, with or without rapid on-site evaluation, for the diagnosis of sarcoidosis: a randomized controlled trial." literature summary: this study describes about conventional transbronchial needle aspiration versus endobronchial ultrasound¿guided transbronchial needle aspiration, with or without rapid on-site evaluation, for the diagnosis of sarcoidosis.Eighty patients with suspected sarcoidosis were randomized 1:1:1:1 into 4 groups: c-tbna with out rose (tbna-nr), c-tbna with rose (tbna-r), ebus-tbna without rose (ebus nr), and ebus-tbna with rose (ebus-r).Ebb and tblb were performed in all patients.Flexible bronchoscopy was performed through the nasal/oral route using the olympus bf-te2 fiberoptic bronchoscope/olympus 1t180 video bronchoscope.C-tbna was performed from the subcarinal (station 7) and/or lower right paratracheal (4r) stations using the 21-g tbna needle (smooth shot na-401d-1521; olympus).Ebus-tbna was performed through the oral route under moderate sedation after insertion of a bite block, using the ebus scope (bf uc-180f; olympus).Image acquisition was obtained using the dedicated ultrasound image processor (eu-me1; olympus) and lymph node sizes and character were recorded.The 21-g dedicated ebus-tbna aspiration needles (vizishot, na-201 sx-4021a; olympus) were used.A total of 74 patients were finally diagnosed with sarcoidosis.Overall, granuloma detection was not significantly different between the 4 groups (68% in tbna-nr, 89% in tbna-r, 84% in ebus-nr, and 83% in ebus-r groups, p = 0.49).The yield of c tbna in the tbna-nr group was lower compared with that in tbna-r group and ebus-tbna in ebus groups (32%, 72%, 68%, and 67% for tbna nr, tbna-r, ebus-nr, and ebus-r groups, respectively, p= 0.04).Additional 20% patients were diagnosed when ebus-tbna was performed following a non-diagnostic bronchoscopy procedure in the tbna-nr group.Sedation requirement and procedure duration were significantly lower with c-tbna as compared with ebus-tbna (p < 0.001).Post-tblb pneumothorax occurred in 4 (5%) patients, 1 in each tbna-nr and ebus nr, and 2 in ebus-r groups and all recovered uneventfully.This study concluded that when performing tbna in the setting of suspected sarcoidosis, we found c-tbna with rose and ebus-tbna (with or without rose) to be superior to c-tbna alone.Whether c-tbna with rose is equivalent to ebus-tbna cannot be determined from our study due to small sample size/low power.Type of adverse events/number of patients, post-tblb pneumothorax - 4 patients.This article includes 5 reports: patient identifier (b)(6): bf-te2.Patient identifier (b)(6): bf-1t180.Patient identifier (b)(6): na-401d-1521.Patient identifier (b)(6): bf-uc180f.Patient identifier (b)(6): na-201sx-4021; since there is no olympus device called "na-201sx-4021a", "na-201sx-4021" was selected.This report is 3 of 5 for patient identifier (b)(6): na-401d-1521.
|
|
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the relationship between the device and the adverse event cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.Olympus will continue to monitor field performance for this device.
|