Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Bone Fracture(s) (1870); Pain (1994)
Date of Event 05/27/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Concomitant devices: persona medial congruent articular surface right 12mm, catalog #: 42522100912, lot #: 64716704.Persona trabecular metal cruciate retaining standard porous femoral component, catalog #: 42502807002, lot #: 64876236.Persona cemented all-poly patella 38mm, catalog #: 42540200038, lot #: 64906870.The complainant has indicated that the product will not be returned to zimmer biomet for investigation, as the device currently remains implanted.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that the patient experienced a tibial bone fracture approximately six (6) months following right knee arthroplasty.A revision procedure is anticipated.Attempts have been made, however, no additional information is available.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional and corrected information.The following sections were updated: b4, g3, g6, h2, h3, h6, h10.The following sections were corrected: b5, h6.X-rays reviewed identified subsidence of the medial tibial component.Tibial fracture was not well-seen, but there was a cortical irregularity along the medial tibial metaphysis, suggesting a fracture.The device history records were reviewed and no discrepancies were identified.Per the package insert, pain and bone fracture are known adverse effects of the system.However, a definitive root cause could not be determined with the information provided.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
It was reported that the patient experienced a tibial bone fracture and pain approximately six (6) months following right knee arthroplasty.The patient is still able to walk, however, a revision procedure is anticipated.Attempts have been made, however, no additional information is available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERSONA TRABECULAR METAL TWO-PEG POROUS TIBIAL COMPONENT RIGHT SIZE G
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer (Section G)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key15064285
Report Number0001822565-2022-02056
Device Sequence Number20237467
Product Code MBH
UDI-Device Identifier00889024510609
UDI-Public(01)00889024510609(17)290831(10)64407255
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K121771
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number42530007902
Device Lot Number64407255
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/24/2022
Supplement Date Received by Manufacturer09/15/2022
Initial Report FDA Received Date07/20/2022
Supplement Report FDA Received Date09/26/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/26/2019
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H10 NARRATIVE
Outcome Attributed to Adverse Event Other;