Additional narrative: devices were not explanted but a revision is expected.Complainant part is not expected to be returned for manufacturer review/investigation.Device is not distributed in the united states, but is similar to device marketed in the usa.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Code not available is for injury/revision surgery needed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10 additional narrative: b5: subsequent follow-up with the customer, additional information was received regarding the event.It was reported that there was unlocking of the screw relative to the plate and retraction of the screws.It was reported that the customer encountered an incident with the 2 lcp plates.It was reported that the implant had been in the patient for 10 days.It was reported that there was a cast immobilization.Investigation summary: product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device history review: part number: 212.107ts, lot number: 698p432, manufacturing site: mezzovico, release to warehouse date: 30 mar 2022, expiration date: 1 mar 2027.A manufacturing record evaluation was performed for the sterile lot number, and no non-conformances were identified.
|