TELEFLEX MEDICAL SDN. BHD. RUSCH CRVD REINF CUFF ET 7.5MM; TUBE, TRACHEAL (W/WO CONNECTOR Back to Search Results
Model Number IPN040970
Medical Device Problem Code Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/22/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported that: "the doctor found cuff leakage during clinical setting before using on patient.No impact on patient.".
 
Additional Manufacturer Narrative
Qn#(b)(4).The sample was returned for evaluation.A visual exam was performed and no defects were observed.Functional testing was then performed and the cuff and pilot balloon were inflated to 25mbar using a calibrated endotest meter.The cuff could not stay inflated.The sample was then immersed in water for leak testing.Air bubbles were observed coming from the cuff indicating there was a leak.The area of leakage was observed under magnification and a cut mark was observed on the cuff.A device history record review was performed and no relevant findings were identified.The complaint of leakage was confirmed; however, a root cause for the issue could not be determined.There is a 100% leak test and visual inspection conducted at the manufacturing facility whereby any leakage would be detected prior to release.It is possible that the failure could be induced during product handling by the user, although this could not be confirmed.
 
Event or Problem Description
It was reported that: "the doctor found cuff leakage during clinical setting before using on patient.No impact on patient.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RUSCH CRVD REINF CUFF ET 7.5MM
Common Device Name
TUBE, TRACHEAL (W/WO CONNECTOR
Manufacturer (Section D)
TELEFLEX MEDICAL SDN. BHD.
perak, west malaysia
Manufacturer (Section G)
TELEFLEX MEDICAL SDN. BHD.
lot no : pt2577 jalen perusahaan
4 kamunting industrial estate
perak, west malaysia 34600
MY   34600
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
9193614124
MDR Report Key15105094
Report Number8040412-2022-00215
Device Sequence Number4213947
Product Code BTR
UDI-Device Identifier14026704340979
UDI-Public14026704340979
Combination Product (Y/N)N
Initial Reporter CountryCH
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility,Company Representative,Distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/04/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberIPN040970
Device Catalogue Number103902-000075
Device Lot Number20ET50
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/04/2022
Supplement Date Received by Manufacturer08/23/2022
Initial Report FDA Received Date07/26/2022
Supplement Report FDA Received Date08/24/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/29/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-