Model Number RA002-5555SLR70
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 07/07/2022
Type of Reportable Event Serious Injury
Event or Problem Description
Information was received that a revision procedure was performed for the removal the magec rod and conversion to a definitive fusion.As per the reporter, there were a lot of black stains in the tissue where the rods had been lengthening.There was no infection or necrosis.No additional information has been provided at this time.Report 2 of 2.
 
Additional Manufacturer Narrative
The device has not been returned for evaluation.The root cause is unable to be determined at this time.A review of the device history records (dhr) confirmed the device met all quality inspections and specifications prior to release.If any additional information is provided, a supplemental report will be submitted.
 
Event or Problem Description
No additional information has been provided.
 
Additional Manufacturer Narrative
The unit has not been returned to the manufacturer for direct investigation.This investigation was performed based on provided intraoperative photographs.During evaluation of the provided intraoperative photographs, presence of possible black discolored tissue was observed along the location where the rod was placed which confirmed the reported tissue discoloration.The unit¿s work order was reviewed and confirmed that the device passed all quality inspections per the acceptance tests prior to shipment.The exact cause of the reported failure mode could not be determined due to the limited clinical information as well as no device return.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MAGEC SPINAL BRACING AND DISTRACTION SYSTEM
Common Device Name
GROWING ROD SYSTEM- MAGNETIC ACTUATION
Manufacturer (Section D)
NUVASIVE SPECIALIZED ORTHOPEDICS, INC.
101 enterprise dr, ste 100
aliso viejo CA 92656
Manufacturer (Section G)
NUVASIVE SPECIALIZED ORTHOPEDICS, INC.
101 enterprise dr, ste 100
aliso viejo CA 92656
Manufacturer Contact
geoff gannon
101 enterprise dr, ste 100
aliso viejo, CA 92656
8583448112
MDR Report Key15106019
Report Number3006179046-2022-00232
Device Sequence Number17456677
Product Code PGN
UDI-Device Identifier00856719002169
UDI-Public856719002169
Combination Product (Y/N)N
Initial Reporter CountrySN
PMA/510(K) Number
K161751
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/19/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberRA002-5555SLR70
Device Lot NumberA161006-01
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/07/2022
Supplement Date Received by Manufacturer08/11/2022
Initial Report FDA Received Date07/26/2022
Supplement Report FDA Received Date08/19/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured10/06/2016
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age14 YR
Patient SexMale
Patient Weight50 KG
-
-