Model Number 786500
Medical Device Problem Code Electrical /Electronic Property Problem (1198)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/27/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The subject device has not yet been received for evaluation.The cause of the issue is unknown at this time.Investigation is ongoing.This report will be supplemented accordingly following investigation.
 
Event or Problem Description
It was reported the unit did not work when opened.No energy flowing through the unit.According to the reporter, the user re-seated the unit however, the unit did not worked.User tried another unit and it worked.There was no patient harm, no user injury reported due to the event.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on device return evaluation.The subject device was received and evaluated.The customer returned a pk button electrode model number 786500 lot number u2109087 for the evaluation of "unit did not work when opened.No energy flowing thru the unit." the model and lot number are based on rma paperwork as there is no visible model and lot number on the electrode.A visual inspection on the as is received condition of the device; noted that the electrode was returned along with a orange "supersect/pk button cable.The electrode and cable was not returned in its original packaging.Inspection identified what appears to be a portion of the shaft that is slightly dented and deformed.The distal end as well as the proximal end have no signs of physical damage or anomalies.A functional test was performed by using a test pk frontloading working element model number eiwe-pkfl.The orange t-shaped superpect/pk button electrode cable was inserted into the slot on the base of the white instrument actuator block with no issues.The electrode was inserted into the working element from the front, advancing the proximal end past the locking mechanism and was engaged with a click.Testing verified that the electrode proximal end was securely fastened.The connector of the electrode cable was plugged into a test 744000 gyrus generator and verified that the generator was able to recognize the customer's electrode.The default settings displayed on the generator, sp2 (200) and des(100).The distal end of the electrode was placed on top of a cotton pad soaked in saline.During testing, a test footswitch was connected and pressed on the yellow cut pedal and observed output power being provided through the distal end of the electrode and then pressed the blue coag pedal and again observed power being provided through the distal end of the electrode.The yellow and blue foot pedals were pressed several times observing output power being provided through the distal end of the electrode.Based on the device evaluation it is unable to determine the cause of customer's issue as during testing, output power was observed being provided with this device.Investigation is ongoing.This report will be supplemented accordingly following investigation.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.A review of the device history record found no deviations that could have caused or contributed to the reported issue.It has been over 1 year since the subject device was manufactured.Based on the results of the investigation, output power was observed.Therefore, the cause of the customer¿s issue could not be determined.This supplemental report includes information added to e2, g2 and h4.Olympus will continue to monitor field performance for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PK BUTTON (BOX OF 5)
Common Device Name
ELECTRODE, ELECTROSURGICAL, ACTIVE, UROLOGICAL
Manufacturer (Section D)
GYRUS ACMI, INC
800 west park drive
westborough MA 01581
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key15108563
Report Number3003790304-2022-00130
Device Sequence Number5255830
Product Code FAS
UDI-Device Identifier00821925039520
UDI-Public00821925039520
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
K093181
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/10/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number786500
Device Lot NumberU2109087
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/29/2022
Supplement Date Received by Manufacturer08/01/2022
09/13/2022
Initial Report FDA Received Date07/26/2022
Supplement Report FDA Received Date08/26/2022
10/11/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/04/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-