|
It was reported on unknown date that dhs/dcs coupling screw was received as blind unit.Product code:338.310 , lot# 237p610.However, it couldn¿t be associated with a complaint or any other existing record.This report is for one (1) dhs/dcs coupling screw this is report 1 of 1 for complaint (b)(4).
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Occupation: reporter is a j&j employee.(b)(4).Part number: 338.310.Lot number: 237p610.Manufacturing site: (b)(4).Release to warehouse date: 22 juli 2021.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.Visual analysis of the returned sample revealed that the dhs/dcs coupling screw was broken from the distal tip, fragment was not returned.A dimensional inspection for the dhs/dcs coupling screw was unable to be performed due to post manufacturing damage.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed as the observed condition of the dhs/dcs coupling screw would contribute to the complained device issue.There is no indication that a design or manufacturing issue has caused the complaint condition and hence the root cause cannot be determined.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|