Model Number MV0413
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/16/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Device expiration date: unknown.Device manufacture date: unknown.
 
Event or Problem Description
It was reported that the bd smartsite¿ vented vial access device, 13 mm experienced leakage.The following information was provided by the initial reporter: ampoule leaked out during drawing up.
 
Event or Problem Description
It was reported that the bd smartsite¿ vented vial access device, 13 mm experienced leakage.The following information was provided by the initial reporter: ampoule leaked out during drawing up.
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d.10.Device available for eval: yes d.10.Returned to manufacturer on: 02-aug-2022.H.6.Investigation summary: one mv0413-0006 sample was received without packaging for investigation; however the customer confirmed the reported sample was from lot 212050.The sample was received attached to a medication vial containing fluid.A visual inspection of the vial confirmed that the rubber septum was partially detached from the top of the vial and with minimal manual manipulation, the septum separated and fell into the vial.Functional testing was performed with a retained 50ml bd syringe and leakage was then confirmed between the connection of the vial access device (vad) and the vial.After carefully removing the vad from the vial, there was found to be a very small observable dent in the rim of the via.The details of this feedback were shared with the legal manufacturer of the product, yukon medical llc, for investigation.A review of the production records from lot 212050 did not identify any in-process testing failures or quality deviations which may have resulted in a report of this nature.A definitive root cause for the leakage could not be determined, however previous investigations have replicated this failure mode if the vial septum is pierced off-center of the target piercing area.The vented vial adaptor device is intended to be inserted at the central circle position of the vial's septum using a vertical force.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD SMARTSITE¿ VENTED VIAL ACCESS DEVICE, 13 MM
Common Device Name
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer (Section G)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15135712
Report Number9616066-2022-01017
Device Sequence Number17451604
Product Code LHI
UDI-Device Identifier10885403228445
UDI-Public10885403228445
Combination Product (Y/N)N
Initial Reporter CountrySZ
PMA/510(K) Number
K122265
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model NumberMV0413
Device Catalogue NumberMV0413
Device Lot Number212050
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/29/2022
Supplement Date Received by Manufacturer08/22/2022
Initial Report FDA Received Date07/29/2022
Supplement Report FDA Received Date09/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-