MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH 32MM STD V40 TAPER VIT HEAD; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH 32MM STD V40 TAPER VIT HEAD; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED Back to Search Results
Model Number 6260-5-132
Medical Device Problem Code Degraded (1153)
Health Effect - Clinical Codes Ambulation or Postural Difficulties (2544); Metal Related Pathology (4530)
Date of Event 07/14/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device noted as returned.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.
 
Event or Problem Description
"trunnionosis stem brace 2 and metal head 32mm +4mm.".
 
Event or Problem Description
"trunnionosis stem brace 2 and metal head 32mm +4mm.".
 
Additional Manufacturer Narrative
Reported event: an event regarding wear involving a metal head was reported.The event was not confirmed.Method & results: product evaluation and results: visual inspection: damage was observed on the head taper.This damage was consistent with the interaction between the head taper and stem trunnion.Slight debris was observed on the articulating surface and taper of the head.Explantation damage observed.Dimensional inspection was not performed because the device was returned damaged.Functional inspection was not performed because the event does not relate to device function.Material analysis not performed as visual inspection provided no indication that the event was a result of a material integrity issue.If further information becomes available additional testing will be performed.Clinician review: a review of the provided medical information by a clinical consultant indicated: "unfortunately, there is little documentation for either of these inquiries and no office notes, operation notes or any other documentation was provided.It appears that either one patient had bilateral total hip arthroplasties, or these inquiries may concern two separate patients.I cannot confirm that any of these events occurred since there is no supporting documentation.In addition, the pi reporting is incomplete without documentation.There is mention that trunnionosis was involved in both of these inquiries which led to revision.The causes of trunnionosis are multifactorial including surgical technique factors such as proper assembly and preparation of the implants, as well as implantation, positioning, orientation, and fixation.Patient factors may also be involved including bmi and activity level, as well as implant factors." product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.Complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that the patient was revised due to trunnionosis.Visual inspection of the returned device indicated damage was observed on the head taper.This damage was consistent with the interaction between the head taper and stem trunnion.Slight debris was observed on the articulating surface and taper of the head.Explantation damage observed."unfortunately, there is little documentation for either of these inquiries and no office notes, operation notes or any other documentation was provided.It appears that either one patient had bilateral total hip arthroplasties, or these inquiries may concern two separate patients.I cannot confirm that any of these events occurred since there is no supporting documentation.In addition, the pi reporting is incomplete without documentation.There is mention that trunnionosis was involved in both of these inquiries which led to revision.The causes of trunnionosis are multifactorial including surgical technique factors such as proper assembly and preparation of the implants, as well as implantation, positioning, orientation, and fixation.Patient factors may also be involved including bmi and activity level, as well as implant factors." no further investigation for this event is possible at this time.If additional information become available to indicate further evaluation is warranted, this record will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
32MM STD V40 TAPER VIT HEAD
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-CORK
ida industrial estate
carrigtwohill NA
EI   NA
Manufacturer Contact
diana rogers
210 centennial avenue
centennial park, elstree
borehamwood, NJ WD6 3-SJ
UK   WD6 3SJ
2018315000
MDR Report Key15154585
Report Number0002249697-2022-01139
Device Sequence Number5208691
Product Code JDI
UDI-Device Identifier07613327012873
UDI-Public07613327012873
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K121308
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2022
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/01/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/31/2023
Device Model Number6260-5-132
Device Catalogue Number6260-5-132
Device Lot Number65660602
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/28/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/15/2022
Supplement Date Received by Manufacturer10/10/2022
Initial Report FDA Received Date08/03/2022
Supplement Report FDA Received Date11/01/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/02/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient SexFemale
-
-