• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STRATTICE RECONSTRUCTIVE TISSUE MATRIX, 30 X 30CM, FIRM; MESH, SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRATTICE RECONSTRUCTIVE TISSUE MATRIX, 30 X 30CM, FIRM; MESH, SURGICAL Back to Search Results
Catalog Number 3030002
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Hernia (2240); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 01/29/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
This legal event is being reported as serious injury due to the reported recurrence and failure to integrate with surgical intervention.Internal investigation into strattice lot sp100503 included a review of the reported information, review of the device history records, and a review of the complaint history records.The investigation resulted in no remarkable findings, including no other complaints reported against the lot and no deviations or related non-conformances revealed during processing.The lot was terminally sterilized within the process parameters and met all qc release criteria.As of (b)(6) 2022, of the 235 devices released to finished goods for lot sp100503, 229 have been distributed with 131 reported as implanted.Based on our internal investigation with no remarkable findings, and without relevant patient factors, a relationship between the strattice and this event could not be determined.Due to the legal process, if additional information is made available during legal proceedings, a supplemental report will be submitted.
 
Event or Problem Description
It was reported through a legal event that a 69 year old female patient had hernia repair surgery on or about (b)(6) 2017.During the hernia repair surgery, the surgeon implanted a strattice mesh; catalog number is 3030002 and lot number is sp100503-242.After surgery, the patient returned to the hospital on or about (b)(6) 2021, reporting sharp and cutting pain, nausea, and having to consistently wear abdominal binders.On or about (b)(6) 2021, the patient was diagnosed with abdominal pain and a recurrent hernia and underwent an exploratory laparotomy, excision of old mesh and abdomen closure.Upon surgical dissection, the surgeon noted failure of the mesh to incorporate into the tissue.The mesh was found adhered to a few spots in the left upper abdomen.The mesh was folded multiple times and wrinkled close to the area where she was experiencing severe pain.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STRATTICE RECONSTRUCTIVE TISSUE MATRIX, 30 X 30CM, FIRM
Common Device Name
MESH, SURGICAL
Manufacturer Contact
christopher belle
1 millennium way
branchburg, NJ 08876
9089471470
MDR Report Key15158083
Report Number1000306051-2022-00126
Device Sequence Number14782594
Product Code FTM
UDI-Device Identifier00818410011796
UDI-Public00818410011796
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
K070560
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 08/03/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/31/2019
Device Catalogue Number3030002
Device Lot NumberSP100503
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/08/2022
Initial Report FDA Received Date08/03/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NO INFORMATION
Outcome Attributed to Adverse Event Required Intervention;
Patient SexFemale
-
-