Model Number 386811
Medical Device Problem Code Material Puncture/Hole (1504)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/05/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that 1 bd cathena¿ safety iv catheter with wings and bd multiguard¿ technology had needle through catheter while introducing the catheter issues.The following information was provided by the initial reporter translated from basque to english : "after the cannula does not advance, the due makes a small backward movement to recanalize and in the second advance there is resistance so decides to remove the cannula and finding at it's exit that the needle had perforated the catheter.".
 
Event or Problem Description
It was reported that 1 bd cathena¿ safety iv catheter with wings and bd multiguard¿ technology had needle through catheter while introducing the catheter issues.The following information was provided by the initial reporter translated from basque to english : "after the cannula does not advance, the due makes a small backward movement to recanalize and in the second advance there is resistance so decides to remove the cannula and finding at it's exit that the needle had perforated the catheter.".
 
Additional Manufacturer Narrative
H6: investigation summary one photo was received by our quality team for evaluation.From the photo, the needle is observed to be pierced through the catheter.A review of the internal manufacturing device records and raw material history files for the reported lot number was performed and no recorded quality problems or rejections to this incident were found.Based on the verbatim, ¿after a correct puncture in the vein, the cannula is advanced to be cannulated in the vein.It does not advance, the due makes a small backward movement to recanalize¿¿, the needle piercing through the catheter was most likely caused by an incorrect insertion technique.Users are recommended to follow the instructions stated in the instructions for use: if the needle is partially or completely withdrawn from the catheter tubing during insertion, do not re-insert the needle into the catheter tubing as damage may occur.Therefore, this non-conformance most likely occurred out of the manufacturing facility.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD CATHENA¿ SAFETY IV CATHETER WITH WINGS AND BD MULTIGUARD¿ TECHNOLOGY
Common Device Name
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BECTON DICKINSON MEDICAL (SINGAPORE)
30 tuas avenue 2
singapore
Manufacturer (Section G)
BECTON DICKINSON MEDICAL (SINGAPORE)
30 tuas avenue 2
singapore
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15160971
Report Number8041187-2022-00421
Device Sequence Number17566613
Product Code FOZ
UDI-Device Identifier00382903868117
UDI-Public00382903868117
Combination Product (Y/N)N
Initial Reporter CountrySP
PMA/510(K) Number
K201717
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/05/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date08/31/2024
Device Model Number386811
Device Catalogue Number386811
Device Lot Number1232895
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/08/2022
Supplement Date Received by Manufacturer08/05/2022
Initial Report FDA Received Date08/03/2022
Supplement Report FDA Received Date08/30/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/20/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-