MAUDE Adverse Event Report: SMITHS MEDICAL INTERNATIONAL, LTD. PORTEX BLUE LINE SACETT SUCTION ABOVE THE CUFF TRA; TUBE, TRACHEAL (W/WO CONNECTOR)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITHS MEDICAL INTERNATIONAL, LTD. PORTEX BLUE LINE SACETT SUCTION ABOVE THE CUFF TRA; TUBE, TRACHEAL (W/WO CONNECTOR) Back to Search Results
Model Number 100/189/070
Medical Device Problem Code Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/04/2021
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the patient who was intubated had to be extubated and re-intubated with a non saccet et tube.The et tube had to be replaced due to cuff failure.There was no patient injury reported.Three devices in total were used on the same patient on the same day.
 
Event or Problem Description
Additional info received 12-jul-22: three devices in total were used on the same patient on the same day.
 
Additional Manufacturer Narrative
Other, other text: no lot number was provided; therefore, device history record review could not be performed.A product sample was received for evaluation.Visual inspection found no anomalies in the cuff, but damage was detected in the inflation line.Due the inflation line is damaged, it's not possible perform the leak functional test to confirm the leak in cuff since the inflation line must be connected to leak tester machine to allow air pass through the tube and confirm the leak in cuff.Based on the analysis conducted in the sample provided, the root cause analysis cannot be addressed due to damage in the inflation line.No corrective action required since the reported failure mode was not confirmed.E4 is unknown.Additional information received (updated b5).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PORTEX BLUE LINE SACETT SUCTION ABOVE THE CUFF TRA
Common Device Name
TUBE, TRACHEAL (W/WO CONNECTOR)
Manufacturer (Section D)
SMITHS MEDICAL INTERNATIONAL, LTD.
boundary road
hythe, kent CT21 6JL
UK  CT21 6JL
Manufacturer (Section G)
NULL
boundary road
hythe, kent CT21 6JL
UK   CT21 6JL
Manufacturer Contact
jim vegel
6000 nathan lane north
dublin 18
minneapolis, MN 55442
MDR Report Key15176200
Report Number3012307300-2022-14853
Device Sequence Number17717586
Product Code BTR
UDI-Device Identifier15019315059520
UDI-Public15019315059520
Combination Product (Y/N)N
Initial Reporter CountryEI
PMA/510(K) Number
K081086
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/12/2025
Device Model Number100/189/070
Device Catalogue Number100/189/070
Device Lot Number3952514
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/15/2022
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/12/2022
Supplement Date Received by Manufacturer10/14/2022
Initial Report FDA Received Date08/05/2022
Supplement Report FDA Received Date10/14/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/06/2020
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-