| Model Number |
515053 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/11/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that the bd phaseal¿ optima injector (n35-o multi) experienced needle exposure during use.The following information was provided by the initial reporter: i wanted to bring to your attention an issue we had with an optima injector yesterday.Injected a hazardous drug into a bag, and when he pulled the syringe off the infusion adapter, the seal came out of the injector leaving the needle exposed within the injector sleeve.Seal piece from inside the injector sleeve is on top of the packaging.I am not sure if anyone else has had this issue.
|
| |
|
Additional Manufacturer Narrative
|
|
A sample is available for evaluation.Upon completion of the investigation, a supplemental report will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported that the bd phaseal¿ optima injector (n35-o multi) experienced needle exposure during use.The following information was provided by the initial reporter: i wanted to bring to your attention an issue we had with an optima injector yesterday.Xxxx injected a hazardous drug into a bag, and when he pulled the syringe off the infusion adapter, the seal came out of the injector leaving the needle exposed within the injector sleeve.Seal piece from inside the injector sleeve is on top of the packaging.I am not sure if anyone else has had this issue.
|
| |
|
Additional Manufacturer Narrative
|
|
The following fields were updated due to additional information: d10: device available for eval yes.D10: returned to manufacturer on: 18-oct-2022.H6: investigation summary one sample and one photo was provided to our quality team for investigation.Through visual inspection, the membrane was observed to have separated from the injector.Further evaluation identified that the hole on the bottom of the membrane was clogged which likely prevented proper assembly between the membrane and injector cannula during assembly.A device history review was performed for lot 2111311, no deviations or non-conformances were identified during the manufacturing process that could have contributed to this issue.Five retained samples of the same lot were used for additional evaluation.The product was visually inspected and no defects were identified, all injectors were properly assembled and no membranes were observed to be clogged.Product undergoes visual and functional inspections throughout the manufacturing process to ensure the quality and functionality of the device.No issues related to this issue were identified during the inspection process.While we cannot identify a direct issue, the clog within the membrane likely prevented proper assembly and lead to the membrane disconnecting from the injector as observed in the product evaluated.
|
| |
|