BLUE BELT TECHNOLOGIES REAL INTELLIGENCE CORI; ORTHOPEDIC STEREOTAXIC INSTRUMENT Back to Search Results
Model Number ROB10024
Device Problem No Apparent Adverse Event (3189)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/21/2022
Event Type  Injury  
Manufacturer Narrative
Internal complaint reference: (b)(4).
 
Event Description
It was reported that, during a cori assisted surgery, there were several bad drill issues, it is believed that the issue comes from the console.The procedure was completed, with a delay of less than 30 min, changing to manual procedure.Patient was not harmed.
 
Manufacturer Narrative
The real intelligence cori, part number rob10024, serial number (b)(6), used for treatment was not returned for evaluation.A relationship between the reported event and the device could not be established.A complaint history review for similar reported/confirmed complaints has identified prior events.A review of manufacturing records indicate the device met all specifications upon release into distribution.The real intelligence cori for knee arthroplasty user manual ((b)(4)) provides guidelines for recovering to a fully manual procedure in the "recovery procedure guidelines, appendix d".The failure mode and associated risk have been anticipated within the risk file.The risk level is still adequate.Although the reported problem was not confirmed through a visual or functional evaluation, factors contributing to the reported symptom may have been associated with console software bug.Based on the investigation, the need for a corrective action is not recommended or required at this time.Should any additional information be received the complaint will be reopened.The failure mode will continue to be closely monitored through complaint investigation and trended through post market surveillance activities.
 
Manufacturer Narrative
H3, h6: the real intelligence cori, part number rob10024, serial number (b)(6), used for treatment, was returned for evaluation.The reported problem could not be confirmed with a visual inspection.The reported problem was not confirmed with a functional evaluation.Test cases and kpc diagnostics were completed without errors with 2 lab drills.A review of the log files and screenshots confirmed the event.Numerous drill errors occurred across multiple cases.A relationship between the reported event and the device could not be established.Although the reported problem was not confirmed through a visual or functional evaluation, factors contributing to the reported symptom may have been associated with faulty drills/drill attachments being used during the cases.No issues were found with the console.Drill (b)(6) was returned on a different complaint (same day of event) and it was found that the drill attachment retaining nut was loose, which may have caused the failures present in the logs.Refer to the real intellignece cori for knee arthroplasty user manual for guidance to recover to a manual case in the event of a system failure.A review of manufacturing records indicate the device met all specifications upon release into distribution.A complaint history review for similar reported/confirmed complaints has identified prior events.A historical review concluded that no prior escalation actions are applicable to the scope of the reported complaint.The failure mode and associated risk have been anticipated within the risk file.The risk level is still adequate.Based on the investigation, the need for a corrective action is not recommended or required at this time.Should any additional information be received the complaint will be reopened.The failure mode will continue to be closely monitored through complaint investigation and trended through post market surveillance activities.
 
Manufacturer Narrative
H3, h6.The real intelligence cori, part number rob10024, serial number (b)(6), used for treatment, was returned for evaluation.The reported problem could not be confirmed with a visual inspection.The reported problem was not confirmed with a functional evaluation.Test cases and kpc diagnostics were completed without errors with 2 lab drills.A review of the log files and screenshots confirmed the event.Numerous drill errors occurred across multiple cases.A relationship between the reported event and the device could not be established.Although the reported problem was not confirmed through a visual or functional evaluation, factors contributing to the reported symptom may have been associated with faulty drills being used during the cases.No issues were found with the console.Refer to the real intellignece cori for knee arthroplasty user manual for guidance to recover to a manual case in the event of a system failure.A review of manufacturing records indicate the device met all specifications upon release into distribution.A complaint history review for similar reported/confirmed complaints has identified prior events.A historical review concluded that no prior escalation actions are applicable to the scope of the reported complaint.The failure mode and associated risk have been anticipated within the risk file.The risk level is still adequate.Based on the investigation, the need for a corrective action is not recommended or required at this time.Should any additional information be received the complaint will be reopened.The failure mode will continue to be closely monitored through complaint investigation and trended through post market surveillance activities.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REAL INTELLIGENCE CORI
Type of Device
ORTHOPEDIC STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
BLUE BELT TECHNOLOGIES
2905 northwest blvd ste 40
plymouth MN 55441
Manufacturer (Section G)
BLUE BELT TECHNOLOGIES
2905 northwest blvd ste 40
plymouth MN 55441
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key15195749
MDR Text Key297569889
Report Number3010266064-2022-00555
Device Sequence Number1
Product Code OLO
UDI-Device Identifier00885556757420
UDI-Public00885556757420
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K193120
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date 02/22/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/09/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberROB10024
Device Catalogue NumberROB10024
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/20/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage A
Patient Sequence Number1
Patient Outcome(s) Other;
-
-