| Model Number |
N/A |
| Medical Device Problem Code |
Material Deformation (2976)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/20/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported "the introducers too easily buckling and becoming bent or the grey peel-a-way end begins to curl back on itself preventing the introducer from entering the vein wall.We were able to easily insert the introducer through the skin over the guide wire for about 1 inch after making a skin nick.However, when we tried to advance the introducer through the vein, we met resistance.When we tried to advance the introducer through the vein, we met resistance.We made a larger nick but had the same outcome.When we removed the introducer i could see and feel the gray edge had rolled back on itself.We had to open an additional midline kit to retrieve another introducer.When we retrieved a new introducer, it advanced easily like it's supposed to.".
|
| |
|
Additional Manufacturer Narrative
|
|
The manufacturer has received the sample and is pending evaluation.Results are expected soon.A lot history review (lhr) of regq0632 showed one other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported "the introducers too easily buckling and becoming bent or the grey peel-a-way end begins to curl back on itself preventing the introducer from entering the vein wall.We were able to easily insert the introducer through the skin over the guide wire for about 1 inch after making a skin nick.However, when we tried to advance the introducer through the vein, we met resistance.When we tried to advance the introducer through the vein, we met resistance.We made a larger nick but had the same outcome.When we removed the introducer i could see and feel the gray edge had rolled back on itself.We had to open an additional midline kit to retrieve another introducer.When we retrieved a new introducer, it advanced easily like it's supposed to.".
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, applicable previous investigation(s), sample analysis, applicable fmea documents, applicable manufacturing records, and labeling.Based on a review of this information, the following was concluded: the complaint of a difficult insertion is confirmed.One 3.5 fr x 7cm microez microintroducer was returned for evaluation.The written note indicated lot: regq0632.The dilator was returned, and the sheath had not been peeled.The sheath was observed to be bent at the proximal end extending from the peelable tabs and in the center region of the sheath tubing.Bunching of the sheath tip was also noted.Microscopic observation of the sheath tip revealed the material to be compressed and bunched inwards.The sheath tip taper transition did not appear to be smooth.It was flat which created a blunt surface.Since the condition of the sheath tip taper likely contributed to the insertion of the device, the complaint is confirmed.Bd is working closely with the manufacturing facility to prevent reoccurrence of the reported event.
|
| |
|