MAUDE Adverse Event Report: ERIKA DE REYNOSA, S.A. DE C.V. CLIC BLOOD CHAMBER; ACCESSORIES, BLOOD CIRCUIT, HEMODIALYSIS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ERIKA DE REYNOSA, S.A. DE C.V. CLIC BLOOD CHAMBER; ACCESSORIES, BLOOD CIRCUIT, HEMODIALYSIS Back to Search Results
Model Number CL10041021
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/24/2022
Type of Reportable Event Malfunction
Event or Problem Description
A user facility reported to fresenius via voluntary medwatch # (b)(4) that a blood leak occurred with a crit-line clip (clic) blood chamber during a patient¿s hemodialysis (hd) treatment.The blood leak was caught immediately by the staff.The machine, a fresenius 2008t hd system, did not alarm.It was reported that the clic blood chamber separated into two parts.The blue sensor disconnected from the part that connects with the dialyzer.The patient was utilizing a fresenius dialyzer and fresenius bloodlines.It was confirmed that the dialyzer and bloodlines had not malfunctioned in any way.There was no defect or damage seen on the clic blood chamber prior to the event.There were no loose connections or issues encountered during prime.The patient¿s estimated blood loss (ebl) was approximately 250 ml.It was confirmed that there was no patient injury, adverse events, or medical intervention required as a result of the reported event.The patient was restarted on the same machine and treatment was completed successfully with new supplies.The sample was available to be returned to the manufacturer for physical evaluation.
 
Additional Manufacturer Narrative
The plant investigation is in process.A supplemental mdr will be submitted upon completion of this activity.
 
Additional Manufacturer Narrative
Additional information: h3 plant investigation: although a sample was reported to be available for manufacturer evaluation, to date no sample has been received and a physical evaluation could not be performed.However, a photograph was received from the customer which shows a separation from the blue chamber body connection to the din connector.This kind of failure mode could be attributed to any of the following: a malfunctioning of the machine that performs the assembly (by not applying the solvent on the din connector), a dryness channel, the din connector not being assembled to the chamber body, or the din connector assembled with a gap greater than the specification.A batch records review was conducted by the manufacturer for the reported lot.There were no non-conformances or abnormalities identified during the manufacturing process which could be associated with the reported event.The entire lot has been sold and distributed.In addition, a device history review was performed and confirmed that the results of the in-progress and final quality control (qc) testing met all requirements.The lot met all specifications for release.The reported event was confirmed based on the provided photograph.
 
Event or Problem Description
A user facility reported to fresenius via voluntary medwatch#: (b)(4) that a blood leak occurred with a crit-line clip (clic) blood chamber during a patient¿s hemodialysis (hd) treatment.The blood leak was caught immediately by the staff.The machine, a fresenius 2008t hd system, did not alarm.It was reported that the clic blood chamber separated into two parts.The blue sensor disconnected from the part that connects with the dialyzer.The patient was utilizing a fresenius dialyzer and fresenius bloodlines.It was confirmed that the dialyzer and bloodlines had not malfunctioned in any way.There was no defect or damage seen on the clic blood chamber prior to the event.There were no loose connections or issues encountered during prime.The patient¿s estimated blood loss (ebl) was approximately 250 ml.It was confirmed that there was no patient injury, adverse events, or medical intervention required as a result of the reported event.The patient was restarted on the same machine and treatment was completed successfully with new supplies.The sample was available to be returned to the manufacturer for physical evaluation.
 
Additional Manufacturer Narrative
H3 plant investigation: the user facility returned complaint samples to the manufacturer for physical evaluation.74 samples were received in their original packaging with product number cl10041021 and lot number 21kr01001.During visual inspection of the returned samples, a separation was noticed in 9 of the samples between the clic port and the din connector.No solvent was found on these samples.The din connector and the clic body port were dimensionally inspected and were found to be acceptable.This kind of failure could be attributed to a malfunctioning of the machine that performs the assembly of the product, by several different causes.A batch records review was conducted by the manufacturer for the reported lot.There were no non-conformances or abnormalities identified during the manufacturing process which could be associated with the reported event.In addition, a device history review was performed and confirmed that the results of the in-progress and final quality control (qc) testing met all requirements.The lot met all specifications for release.Based on the sample evaluation that was performed, the alleged failure mode was able to be confirmed.
 
Event or Problem Description
A user facility reported to fresenius via voluntary medwatch # (b)(4) that a blood leak occurred with a crit-line clip (clic) blood chamber during a patient¿s hemodialysis (hd) treatment.The blood leak was caught immediately by the staff.The machine, a fresenius 2008t hd system, did not alarm.It was reported that the clic blood chamber separated into two parts.The blue sensor disconnected from the part that connects with the dialyzer.The patient was utilizing a fresenius dialyzer and fresenius bloodlines.It was confirmed that the dialyzer and bloodlines had not malfunctioned in any way.There was no defect or damage seen on the clic blood chamber prior to the event.There were no loose connections or issues encountered during prime.The patient¿s estimated blood loss (ebl) was approximately 250 ml.It was confirmed that there was no patient injury, adverse events, or medical intervention required as a result of the reported event.The patient was restarted on the same machine and treatment was completed successfully with new supplies.The sample was available to be returned to the manufacturer for physical evaluation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLIC BLOOD CHAMBER
Common Device Name
ACCESSORIES, BLOOD CIRCUIT, HEMODIALYSIS
Manufacturer (Section D)
ERIKA DE REYNOSA, S.A. DE C.V.
mike allen #1331
parque industrial reynosa
reynosa 88780
MX  88780
Manufacturer (Section G)
ERIKA DE REYNOSA, S.A. DE C.V.
director, quality systems
1100 e, military hwy, suite c
pharr TX 78577
Manufacturer Contact
jessica trujillo
920 winter st
waltham, MA 02451
6174175172
MDR Report Key15218506
Report Number0008030665-2022-00935
Device Sequence Number12444900
Product Code KOC
UDI-Device Identifier00840861100552
UDI-Public00840861100552
Combination Product (Y/N)N
Initial Reporter StateDC
Initial Reporter CountryUS
PMA/510(K) Number
K152953
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility
Initial Reporter Occupation Nurse
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/31/2024
Device Model NumberCL10041021
Device Catalogue NumberCL10041021
Device Lot Number21KR01001
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Device AgeMO
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/21/2022
Supplement Date Received by Manufacturer09/01/2022
10/24/2022
Initial Report FDA Received Date08/12/2022
Supplement Report FDA Received Date09/19/2022
10/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/22/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
FRESENIUS 2008T MACHINE; FRESENIUS 2008T MACHINE; FRESENIUS 2008T MACHINE; FRESENIUS BLOODLINES; FRESENIUS BLOODLINES; FRESENIUS BLOODLINES; FRESENIUS OPTIFLUX DIALYZER; FRESENIUS OPTIFLUX DIALYZER; FRESENIUS OPTIFLUX DIALYZER
Patient Age72 YR
Patient SexMale
-
-