BOSTON SCIENTIFIC CORPORATION SENSOR; STYLET FOR CATHETER, GASTRO-UROLOGY Back to Search Results
Model Number M0066703121
Medical Device Problem Codes Detachment of Device or Device Component (2907); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/28/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).The device has not been received for analysis.Upon receipt and completion of the problem analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
 
Event or Problem Description
It was reported to boston scientific corporation that a sensor wire was used during a flexible ureteroscopy procedure on (b)(6) 2022.During the procedure, the shrink sleeve was detached.The detached portion was removed from the patient.The procedure was completed with the same original guidewire.There were no patient complications reported as a result of this event.
 
Additional Manufacturer Narrative
Block h6 (device codes): device code a0501 captures the reportable event of shrink sleeve detached.Block d6 (impact codes): impact code f23 captures the reportable event of unexpected medical intervention.Block h10: the returned sensor wire was analyzed.The returned product was found with its sections complete (urethane tip, sleeve and ptfe coil), however, the ptfe was peeled at the long of the wire.The reported event was not confirmed.Based on the condition of the returned device, engineers determined that the problem observed is related to the handling / manipulation, excess of force applied to the device, probably caused when the user used the device.According to the information provided the event occurred during procedure.Boston scientific has determined the most probable cause of this complaint is adverse event related to procedure.It is most likely that the adverse event occurred during the procedure and the device had no influence on event which led to the reported event.
 
Event or Problem Description
It was reported to boston scientific corporation that a sensor wire was used during a flexible ureteroscopy procedure on (b)(6) 2022.During the procedure, the shrink sleeve was detached.The detached portion was removed from the patient.The procedure was completed with the same original guidewire.There were no patient complications reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SENSOR
Common Device Name
STYLET FOR CATHETER, GASTRO-UROLOGY
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
2546 calle primera
alajuela
CS  
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key15237427
Report Number3005099803-2022-04542
Device Sequence Number6293433
Product Code EZB
UDI-Device Identifier08714729257349
UDI-Public08714729257349
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/23/2025
Device Model NumberM0066703121
Device Catalogue Number670-312
Device Lot Number0029465881
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/28/2022
Supplement Date Received by Manufacturer09/22/2022
Initial Report FDA Received Date08/16/2022
Supplement Report FDA Received Date10/14/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/24/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-