Model Number 1804300-38
Medical Device Problem Codes Material Rupture (1546); Device Dislodged or Dislocated (2923); Activation Failure (3270)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/22/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The stent delivery system was received.The stent remains implanted.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.Na.
 
Event or Problem Description
It was reported that the procedure was performed to treat a lesion in the right coronary artery.The 3.0 x 38 mm xience skypoint stent delivery system was advanced to the target lesion.An attempt was made to deploy the stent; however, the pressure did not increase and the stent dislodged from the delivery system.The stent delivery system was removed without difficulty, and a non-abbott balloon catheter was advanced to fully open and implant the stent.There was no adverse patient effect or clinically significant delay.No additional information was provided.
 
Event or Problem Description
Subsequent to the initial mdr, the following information was provided: during the procedure, an attempt was made to deploy the xience skypoint stent; however, the balloon failed to fully expand and a balloon rupture occurred.Leak of contrast agent was noted on imaging.The stent was deployed from the delivery system, but required additional balloon dilatation, using a non-abbott dilatation catheter, to fully deploy the stent.No additional information was provided.
 
Additional Manufacturer Narrative
The device was returned for analysis.The stent remains implanted.The reported material rupture was confirmed.The stent implant was not returned therefore the reported activation failure could not be confirmed.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no similar incidents from this lot.The investigation was unable to determine a conclusive cause for the reported material rupture; however, factors that may contribute to material ruptures include, but are not limited to, material damage, interactions with other devices or interaction with lesion calcification and/or tortuosity of the lesion.There was no damage or leak noted to the stent delivery system (sds) during the inspection prior to use or during preparation of the device, which suggests a product quality issue did not contribute to the reported difficulties.The reported activation failure and subsequent treatment appears to be related to operational context of the procedure.There is no indication of a product quality issue with respect to manufacture, design or labeling.H6 medical device problem coding 2923 - removed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE SKYPOINT DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Common Device Name
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key15244989
Report Number2024168-2022-08852
Device Sequence Number4655347
Product Code NIQ
UDI-Device Identifier08717648233289
UDI-Public08717648233289
Combination Product (Y/N)Y
Initial Reporter CountryJA
PMA/510(K) Number
P110019
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/27/2024
Device Model Number1804300-38
Device Catalogue Number1804300-38
Device Lot Number1012541
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/08/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/25/2022
Supplement Date Received by Manufacturer09/13/2022
Initial Report FDA Received Date08/17/2022
Supplement Report FDA Received Date09/23/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/28/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-