Model Number 02-022-51-3509
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Failure of Implant (1924); Pain (1994)
Date of Event 07/25/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Pending evaluation.Concomitant device(s): 02-020-13-0335, 6118379 - truliant cr cem fem cr cem right sz 3.5.02-022-45-3535, 6036478 - truliant tib fit tray cem sz 3.5f / 3.5t.200-02-38, 6067876 - three peg patella 38mm.201-78-15, 5972593 - holding pin mini sharp point 4 ok.521-78-23, s017632 - threading pin size 2.3 collared 2pk.521-78-32, s005968 - threading pin size 3.0 collarless 2pk.521-78-32, s006139 - threading pin size 3.0 collarless 2pk.521-78-36, s003456 - threading pin size 5.1 collarless 2pk.
 
Event or Problem Description
As reported, the patient returned to clinic with pain and tightness.This week on monday the patient was revised again due to pain and tightness.Surgeon noted non compliance with post op instructions.The insert was dropped from 15 to 12mm and rom was significantly improved.Implants not available to return.No further information available.Patient last known to be in stable condition.
 
Additional Manufacturer Narrative
Section h10: (h3) based on review of all available information, there is no evidence to suggest that the reported event is related to any design or manufacturing issues.The cause of the subsequent revision cannot be conclusively determined; however, it is most likely related to the patient¿s underlying condition and noncompliance.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay corrected information.The following sections were corrected: b1, b2, d1, d4, d6a, d8, d10, g4, h4, h6 clinical code, medical device problem code, component code, investigation findings codes.(d10) concomitant device(s): 02-020-11-0245, 5382406 - truliant ps cem fem ps cem left sz 4.5.02-022-45-4535, 5024223 - truliant tib fit tray cem sz 4.5f/3.5t.200-02-35, 5200293 - three peg patella 35mm.201-78-15, 5197939 - holding pin mini sharp point 4 pk.521-78-31, 5394106 - threaded pin size 2.6 collarless 2pk.Should additional relevant information be obtained, a follow-up mdr will be submitted accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRULIANT TIB IMP PSC INSERT SZ 4.5, 15MM
Common Device Name
PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
Manufacturer (Section D)
EXACTECH, INC.
2320 nw 66 court
gainesville FL 32653
Manufacturer (Section G)
EXACTECH, INC.
2320 nw 66 ct
gainesville FL 32653
Manufacturer Contact
kate jacobson
3523771140
MDR Report Key15245404
Report Number1038671-2022-00928
Device Sequence Number12238644
Product Code JWH
UDI-Device Identifier10885862305411
UDI-Public10885862305411
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K171045
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/22/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/10/2026
Device Model Number02-022-51-3509
Device Catalogue Number02-022-44-4515
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/29/2022
Supplement Date Received by Manufacturer08/22/2022
01/16/2026
Initial Report FDA Received Date08/17/2022
Supplement Report FDA Received Date09/15/2022
01/22/2026
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured04/11/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H10; SEE H11
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient SexFemale
-
-