CONSOLIDATED MEDICAL EQUIPMENT COMPANY 1MM MICROBIOLOGY BRUSH 5/CS; BRUSH, BIOPSY, BRONCHOSCOPE (NON-RIGID)
|
Back to Search Results |
|
| Model Number |
130 |
| Medical Device Problem Code |
Material Fragmentation (1261)
|
| Health Effect - Clinical Code |
Foreign Body In Patient (2687)
|
| Date of Event |
07/23/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
The customer reported that the device, 130, 1mm microbiology brush 5/cs, was being used during an internal/external biliary drain procedure on (b)(6) 2022 when it was reported ¿tubing broken off in patient and was not able to be removed.¿.The reporter also stated that the patient had prolonged hospitalization.Further assessment questions were sent, and the reporter gave further explanation of the procedure by saying, ¿4 french delivery catheter was subsequently advanced over the wire to the level of the ampulla for acquisition of brush biopsy.Unsuccessful brush biopsy samples due to advancement of conmed catheter became kinked and could not be removed over the wire.The hub of the catheter was cut and removed.Attempts were made to remove catheter through a 6fr vascular sheath without success.¿.The procedure was completed after a 30-minute delay.The patient was reported as currently being in the hospital.This report is being raised on the basis of injury due to device component being left in the patient.
|
| |
|
Additional Manufacturer Narrative
|
|
The device will not be returned for evaluation and no photographic evidence was provided therefore the event cannot be verified.The manufacturing documents from the device history record have been reviewed with special attention to the manufacturing and inspection of the product.The product released for distribution was found to have met all specifications prior to shipment.This is the only complaint for this lot number and failure mode within the past two years.A two-year review of complaint history revealed there has been a total of one complaint, regarding one device, for this device family and failure mode.During this same time frame 40,345 devices have been manufactured and shipped worldwide.Should all the complaint devices have been found confirmed for this reported failure, the rate of failure would be 0.00002.Per the instructions for use, the user is advised to inspect the catheter for any damage which may have occurred in transit.Avoid touching the catheter near the plug as the warmth from your hands may cause the plug to melt.Check visually for kinked, bent, or flattened areas.Check the handle apparatus for any visible damage but be careful not to move it and expel the plug.Do not use if the catheter or handles appear damaged in any way.This issue will continue to be monitored through the complaint system to assure patient safety.
|
| |
|
Search Alerts/Recalls
|
|
|