|
C.R. BARD, INC. (BASD) -3006260740 PER-Q-CATH PLUS 2F SINGLE-LUMEN PICC; CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
|
Back to Search Results |
|
| Model Number |
N/A |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
05/03/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that when the doctor test to flush, he found that the distal end of the tube began to leak, so he applied for a replacement.
|
| |
|
Additional Manufacturer Narrative
|
|
The manufacturer has received the sample and is pending evaluation.Results are expected soon.A lot history review (lhr) review is not possible, as no manufacturing lot number has been provided by the complainant.
|
| |
|
Event or Problem Description
|
|
It was reported that when the doctor test to flush, he found that the distal end of the tube began to leak, so he applied for a replacement.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, complaint and lot history review, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a leak was confirmed.The product returned for evaluation was one 2 fr per-q-cath with an attached t-lock.The damage observed in the returned sample was characteristic of over-pressurization (burst) damage.This can occur through the use of syringes smaller than 10ml, by flushing against an occlusion, or due to excessive force applied during infusion procedures.The returned product sample was evaluated, and a relatively large split was observed near the 10 cm depth marker.This catheter damage was typical of a burst, and the characteristics observed which supported this type of failure included: ¿ granular fracture surface texture (typical of tearing failure modes); ¿ rough and somewhat uneven edges of the split; ¿ tensile weakness at the fracture site (due to material ballooning prior to burst).An occlusion was observed distal to the burst site, and this may have contributed to the failure.Forceful flushing against an occlusion can cause this type of failure.An examination of the catheter structure revealed no potential damage/defect related to manufacture of the product.A lot history review (lhr) of redt1755 showed no other similar product complaint(s) from this lot number.
|
| |
|
Search Alerts/Recalls
|
|
|