|
When pinned and pulled, the stent flowered out, but the last 1 cm of the stent would not exit out.The device was completely pulled back to the hub.The stent should have completely deployed at this point.The user pulled the whole deployment system back to deploy stent in target site.This occurred with every stent used in this case: (b)(6)¿ g43773, lot number c1753166.(b)(6)¿ g43773, lot number c1794186.(b)(6)¿ g43773, lot number c1633402.(b)(6)¿ g36048, lot number c1778086.(b)(6)¿ g36048, lot number c1810418.Did any unintended section of the device remain inside the patient¿s body? no.Was the patient hospitalized or was there prolonged hospitalization? no.Did the patient require any additional procedures due to this occurrence? no.Did the product cause or contribute to the need for additional procedures? no.Has the complainant reported any adverse effects on the patient due to this occurrence? no.Has the complainant reported that the product caused or contributed to the adverse effects? na.At what stage of the procedure did the complaint occur? stent placement.Details of access sheath used (name, fr size, length)? 5 fr terumo slender sheath.Did the patient require any additional procedures as a result of this event? no.What intervention (if any) was required? none.As per answers to additional questions on 17-jun-2022 1.Are images of the device or procedure available? n/a, yes, no- no.2.What was the target location for the stent?- sfa.3.Was the device used percutaneously? n/a, yes, no- yes.4.Was the product inspected for kinks or damage before use? n/a, yes, no- yes.5.Was the device flushed through both flushing port before the procedure, as per ifu? n/a, yes, no-.6.Was pre-dilation performed ahead of placement of the stent? n/a, yes, no- yes.7.Was post-dilation performed after the placement of the stent? n/a, yes, no- yes.8.Details of the wire guide used (name, diameter, hydrophilic)?- info not available.9.Did the patient exhibit difficult or altered anatomy (if altered please specify how it is altered)? n/a, tortuous, calcified, altered- calcified.10.Was resistance encountered when advancing the wire guide to the target location? n/a, yes, no- yes.11.Was resistance encountered when advancing the delivery system to the target location? n/a, yes, no- no.12.How did the physician deal with this resistance? n/a.13.Was the approach ipsilateral or contralateral? n/a, ipsilateral, contralateral- contralateral.If contralateral, was the bifurcation angle steep? n/a, yes, no- no.14.Did the tip of the delivery system cross the target location? n/a, yes, no- yes.15.Was the delivery system tracked around a tight angle in the patient anatomy? n/a, yes, no- no.16.Was the delivery system damaged/kinked/twisted during deployment? n/a, yes, no- no.17.Was the handle pulled towards the hub during deployment? n/a, yes, no- not sure.18.Was the delivery system pushed during deployment? n/a, yes, no- not sure.19.Was the stent deployed smoothly / without resistance? n/a, yes, no- no.If no, please detail any difficulty experienced during deployment: the doctor pin and pulled the delivery system until it was hubbed, but the stent wouldn¿t come off the delivery system.The doctor had to ¿shake¿ the deliver system to get the stent to come off.20.What artery was the stent placed in? sfa.21.Was the stent fully deployed from the delivery system prior to removal of the delivery system? n/a, yes, no- yes.22.Did the patient have any pre-existing conditions? n/a, yes, no- no.23.Were any other defects (other than the complaint issue) observed on the delivery system prior to return (e.G.Kink)? n/a, yes, no- no.Off label use confirmed on (b)(6) 2022 for intended placement in sfa.
|