| Model Number |
324912 |
| Medical Device Problem Code |
Defective Device (2588)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/22/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported that 2 bd veo¿ insulin syringes with bd ultra-fine¿ needle 1ml 6mm (15/64") 31g stopper was deformed.The following information was provided by the initial reporter: consumer stated, stopper was crooked in two syringes prior to use.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: investigation summary no samples (including photos) were returned therefore the complaint could not be confirmed and the root cause is undetermined.A review of the device history record was completed for batch# 0342354.All inspections were performed per the applicable operations qc specification.There were zero (0) notifications noted that pertained to the complaint.Embecta was not able to duplicate or confirm the customer¿s indicated failure as no samples or photos were returned.Root cause cannot be determined at this time as the issue is unconfirmed as no samples or photos were returned.H3 other text : see h10.
|
| |
|
Event or Problem Description
|
|
It was reported that 2 bd veo¿ insulin syringes with bd ultra-fine¿ needle 1ml 6mm (15/64") 31g stopper was deformed.The following information was provided by the initial reporter: consumer stated, stopper was crooked in two syringes prior to use.
|
| |
|
Additional Manufacturer Narrative
|
|
The following fields were updated due to additional information: d.9.Device available for eval?: yes.D.9.Returned to manufacturer on: 12-sep-2022.H.6.Investigation summary: customer returned (2) 1ml bd insulin syringes in an open polybag from lot# 0342354.The customer reported that the stopper was crooked in two syringes, and that there were air bubbles in the barrel of a third syringe.The samples were examined, and it was observed that the rubber stopper on both syringes was disfigured within the respective barrel.Neither syringe exhibited air bubbles or barrel damage.Manufacturing (holdrege) will be notified of the observed issue.A review of the device history record was completed for batch# 0342354.All inspections were performed per the applicable operations qc specifications.There were zero (0) notifications noted that pertained to the complaint.Based on the samples and/or photo(s) received the investigation concluded: - confirmed: embecta was able to duplicate or confirm the customer¿s indicated failure (stopper damaged) complaints received for this device and reported condition will continue to be tracked and trended.Information will be captured on trend reports and monitored monthly.Our business team regularly reviews the collected data for identification of emerging trends.Date complaint received in holdrege: 04-oct -2022 issue: visual inspection of the syringe found the stopper was wedged to one side and disfigured/damaged within the barrel.No damages or bubbles were found on the barrel.Analysis of sample: damaged stopper process: the automatic syringe assembly machine feeds 1cc/ml syringe components (cannulated and shielded barrel, stopper, plunger, and cap) and assembles these components.This machine consists of a barrel-cleaning dial, lubrication dial, plunger/stopper assembly dial, syringe assembly dial, and various inspection and transfer dials.Investigation: a review of the device history record and leading 2lean (l2l) was completed for batch# 0342354.All inspections were performed per the applicable operations qc specifications.There were zero (0) notifications noted that pertained to the complaint.Root cause ¿ there were no quality notifications or dispatches that pertained to the complaint; therefore, no root cause can be determined.Corrective action- ¿ no corrective actions have been determined quality: complaints received for this device and reported conditions will continue to be tracked and trended.Information will be captured on trend reports and monitored.Our business team regularly reviews the collected data for the identification of emerging trends.
|
| |
|
Event or Problem Description
|
|
It was reported that 2 bd veo¿ insulin syringes with bd ultra-fine¿ needle 1ml 6mm (15/64") 31g stopper was deformed.The following information was provided by the initial reporter: consumer stated, stopper was crooked in two syringes prior to use.
|
| |
|