MAUDE Adverse Event Report: BD MEDICAL - DIABETES CARE BD VEO¿ INSULIN SYRINGES WITH BD ULTRA-FINE¿ NEEDLE 1ML 6MM (15/64") 31G; PISTON SYRINGE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD MEDICAL - DIABETES CARE BD VEO¿ INSULIN SYRINGES WITH BD ULTRA-FINE¿ NEEDLE 1ML 6MM (15/64") 31G; PISTON SYRINGE Back to Search Results
Model Number 324912
Medical Device Problem Code Defective Device (2588)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/22/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that 2 bd veo¿ insulin syringes with bd ultra-fine¿ needle 1ml 6mm (15/64") 31g stopper was deformed.The following information was provided by the initial reporter: consumer stated, stopper was crooked in two syringes prior to use.
 
Additional Manufacturer Narrative
H6: investigation summary no samples (including photos) were returned therefore the complaint could not be confirmed and the root cause is undetermined.A review of the device history record was completed for batch# 0342354.All inspections were performed per the applicable operations qc specification.There were zero (0) notifications noted that pertained to the complaint.Embecta was not able to duplicate or confirm the customer¿s indicated failure as no samples or photos were returned.Root cause cannot be determined at this time as the issue is unconfirmed as no samples or photos were returned.H3 other text : see h10.
 
Event or Problem Description
It was reported that 2 bd veo¿ insulin syringes with bd ultra-fine¿ needle 1ml 6mm (15/64") 31g stopper was deformed.The following information was provided by the initial reporter: consumer stated, stopper was crooked in two syringes prior to use.
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d.9.Device available for eval?: yes.D.9.Returned to manufacturer on: 12-sep-2022.H.6.Investigation summary: customer returned (2) 1ml bd insulin syringes in an open polybag from lot# 0342354.The customer reported that the stopper was crooked in two syringes, and that there were air bubbles in the barrel of a third syringe.The samples were examined, and it was observed that the rubber stopper on both syringes was disfigured within the respective barrel.Neither syringe exhibited air bubbles or barrel damage.Manufacturing (holdrege) will be notified of the observed issue.A review of the device history record was completed for batch# 0342354.All inspections were performed per the applicable operations qc specifications.There were zero (0) notifications noted that pertained to the complaint.Based on the samples and/or photo(s) received the investigation concluded: - confirmed: embecta was able to duplicate or confirm the customer¿s indicated failure (stopper damaged) complaints received for this device and reported condition will continue to be tracked and trended.Information will be captured on trend reports and monitored monthly.Our business team regularly reviews the collected data for identification of emerging trends.Date complaint received in holdrege: 04-oct -2022 issue: visual inspection of the syringe found the stopper was wedged to one side and disfigured/damaged within the barrel.No damages or bubbles were found on the barrel.Analysis of sample: damaged stopper process: the automatic syringe assembly machine feeds 1cc/ml syringe components (cannulated and shielded barrel, stopper, plunger, and cap) and assembles these components.This machine consists of a barrel-cleaning dial, lubrication dial, plunger/stopper assembly dial, syringe assembly dial, and various inspection and transfer dials.Investigation: a review of the device history record and leading 2lean (l2l) was completed for batch# 0342354.All inspections were performed per the applicable operations qc specifications.There were zero (0) notifications noted that pertained to the complaint.Root cause ¿ there were no quality notifications or dispatches that pertained to the complaint; therefore, no root cause can be determined.Corrective action- ¿ no corrective actions have been determined quality: complaints received for this device and reported conditions will continue to be tracked and trended.Information will be captured on trend reports and monitored.Our business team regularly reviews the collected data for the identification of emerging trends.
 
Event or Problem Description
It was reported that 2 bd veo¿ insulin syringes with bd ultra-fine¿ needle 1ml 6mm (15/64") 31g stopper was deformed.The following information was provided by the initial reporter: consumer stated, stopper was crooked in two syringes prior to use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD VEO¿ INSULIN SYRINGES WITH BD ULTRA-FINE¿ NEEDLE 1ML 6MM (15/64") 31G
Common Device Name
PISTON SYRINGE
Manufacturer (Section D)
BD MEDICAL - DIABETES CARE
1329 west highway 6
holdrege NE 68949
Manufacturer (Section G)
BD MEDICAL - DIABETES CARE
1329 west highway 6
holdrege NE 68949
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15261706
Report Number1920898-2022-00567
Device Sequence Number17614112
Product Code FMF
UDI-Device Identifier00382903249121
UDI-Public00382903249121
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
K190054
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Consumer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/10/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date12/31/2025
Device Model Number324912
Device Catalogue Number324912
Device Lot Number0342354
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/22/2022
Supplement Date Received by Manufacturer08/23/2022
10/10/2022
Initial Report FDA Received Date08/19/2022
Supplement Report FDA Received Date09/12/2022
10/26/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured12/07/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-