Model Number 102096-67A
Medical Device Problem Code Failure to Sense (1559)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/23/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The manufacturer is currently performing an investigation and will provide the results with the supplemental report.
 
Event or Problem Description
On (b)(6) 2022, senseonics was made aware of an incident where user received an early sensor replacement alert resulting in early sensor removal.
 
Additional Manufacturer Narrative
The sensor's in vitro qc was inconclusive due to the damaged hydrogel when the rma was received in-house.However, the investigation confirmed the customer's complaint via sensor's in-vivo data review.The root cause of the failure was likely to be delamination of the photodiodes from the epoxy bonding in the sensor.The investigation shows that the system correctly disabled the sensor due to performance failure (low overall glucose signals leading to msp) and the system's self-test functions are working normally.The sensor retired outside of the replacement policy period, thus the rma was issued for return of the sensor only.The user was advised to confirm their blood glucose with a blood glucose meter until a new sensor is inserted.D4.Updated additional device information.D6a.Implanted date updated to on (b)(6) 2022.H3.Device evaluated by manufacturer? yes.H4.Device manufacturer date updated to 03 may 2021.H6.Type of investigation updated to 10.H6.Investigation findings updated to 114.H6.Investigation conclusions updated to 4307.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVERSENSE SENSOR
Common Device Name
EVERSENSE CONTINUOUS GLUCOSE MONITOR SYSTEM
Manufacturer (Section D)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20875 7005
Manufacturer (Section G)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20875 7005
Manufacturer Contact
vallikannu somasundaram
20451 seneca meadows parkway
germantown, MD 20875-7005
MDR Report Key15270406
Report Number3009862700-2022-00134
Device Sequence Number6763154
Product Code QHJ
UDI-Device Identifier00817491022349
UDI-Public817491022349
Combination Product (Y/N)Y
Initial Reporter CountryUS
PMA/510(K) Number
P160048
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/30/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date04/23/2022
Device Model Number102096-67A
Device Catalogue NumberFG-4200-00-301
Device Lot NumberWP08507
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/16/2022
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/30/2022
Supplement Date Received by Manufacturer07/30/2022
Initial Report FDA Received Date08/22/2022
Supplement Report FDA Received Date11/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/03/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age59 YR
Patient SexMale
-
-